Skip to main content
Grant Estimator

Panasonic FV-0810VSSAB1 Exhaust Fan Specifications

ENERGY STAR PD #4429347 · Bathroom/Utility Room · Qualified 2025-04-25
Verified Specification Summary

The Panasonic FV-0810VSSAB1 (Whisper Value) moves 100 CFM at 0.1 in. w.g. (102.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 8.1 CFM/W efficacy, sizing bathrooms up to 102 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0810VSSAB1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 102.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.1 CFM/W (#338/1,145)
Static Retention
102.5% @ 0.25"
Motor Draw
12.3 W (4.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0810VSSAB1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0810VSSAB1 (EPA filing PD #4429347) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 102.5 CFM out of 100 CFM (102.5% retention, 14.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Panasonic maintains 92 active ENERGY STAR blowers; FV-0810VSSAB1 (series: Whisper Value) (PD #4429347) gained qualification on 2025-04-25. Lighting kit: No. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.3 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 107.7 kWh/yr (~$17.23/yr) continuously. Closest competing matches include Delta ITG100ELED (100.0 CFM) and Delta ITG100RLED (100.0 CFM).

How does duct geometry alter Panasonic FV-0810VSSAB1 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Panasonic FV-0810VSSAB1?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-0810VSSAB1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0810VSSAB1 / Whisper Value PD ID 4429347 (Qualified 2025-04-25)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (102.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Panasonic FV-0810VSSAB1 ventilate safely?

Sizing outputs below convert Panasonic FV-0810VSSAB1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0810VSSAB1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 102 sq ft1 CFM/sq ft @ 102.5 CFM
Tall Bath (9-ft Ceiling)Up to 91 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 52 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.5 kWh/yr (~$0.72/yr)12.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2107.7 kWh/yr (~$17.23/yr)12.3 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Panasonic FV-0810VSSAB1 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Will Panasonic FV-0810VSSAB1 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Panasonic FV-0810VSSAB1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Where should contractors skip Panasonic FV-0810VSSAB1 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic FV-0810VSSAB1 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 52 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 102 sq ft with 8-ft ceilings (91 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Panasonic FV-0810VSSAB1?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-0810VSSAB1.

How much power does Panasonic FV-0810VSSAB1 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Panasonic FV-0810VSSAB1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Panasonic FV-0810VSSAB1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0810VSSAB1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0810VSSAB1?

Panasonic FV-0810VSSAB1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0810VSSAB1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0810VSSAB1's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Panasonic FV-0810VSSAB1 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0810VSSAB1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Panasonic FV-0810VSSAB1?

Rule out Panasonic FV-0810VSSAB1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Panasonic FV-0810VSSAB1 capacity?

Because static drag at 0.25 in. w.g. lowers Panasonic FV-0810VSSAB1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Panasonic FV-0810VSSAB1 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Panasonic FV-0810VSSAB1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories