Panasonic FV-0811RF1 Exhaust Fan Specifications

ENERGY STAR PD #2390259 · Bathroom/Utility Room · Qualified 2022-01-07
Verified Specification Summary

The Panasonic FV-0811RF1 (whisper Remodel) moves 100 CFM at 0.1 in. w.g. (93.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 3.8 CFM/W efficacy, sizing bathrooms up to 93 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0811RF1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 93.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
93.1% @ 0.25"
Motor Draw
26.3 W (9.6 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0811RF1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0811RF1 (EPA filing PD #2390259) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 93.1 CFM out of 100 CFM (93.1% retention, 5.4 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU FV-0811RF1 (series: whisper Remodel) (PD #2390259) certified since 2022-01-07. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.3 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 230.4 kWh/yr (~$36.86/yr) continuously. Closest competing matches include Hunter 90064A (100.0 CFM) and Hunter 90065A (100.0 CFM).

How does duct geometry alter Panasonic FV-0811RF1 static pressure?

Smooth 3 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Panasonic FV-0811RF1?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-0811RF1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0811RF1 / whisper Remodel PD ID 2390259 (Qualified 2022-01-07)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (93.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Panasonic FV-0811RF1 ventilate safely?

Sizing outputs below convert Panasonic FV-0811RF1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0811RF1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 93 sq ft1 CFM/sq ft @ 93.1 CFM
Tall Bath (9-ft Ceiling)Up to 82 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 43 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2230.4 kWh/yr (~$36.86/yr)26.3 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Panasonic FV-0811RF1 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hunter 90064A 100 / 89.6 CFM 1.5 sones 3.9 CFM/W 4 in. diameter
Hunter 90065A 100 / 89.6 CFM 1.5 sones 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ106MB 100 / 92.8 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Anzzi EF-AZ106WH 100 / 92.8 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Fantech SMPL100 (484302) 100 / 91.2 CFM 1.5 sones 4.0 CFM/W 4 in. diameter

Will Panasonic FV-0811RF1 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Panasonic FV-0811RF1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Panasonic FV-0811RF1 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic FV-0811RF1.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 43 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 93 sq ft with 8-ft ceilings (82 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 3 in. diameter

What key rules and numbers govern Panasonic FV-0811RF1?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-0811RF1.

Which bathroom layouts should pick a larger blower than Panasonic FV-0811RF1?

Do not force Panasonic FV-0811RF1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Panasonic FV-0811RF1 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Panasonic FV-0811RF1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.

Will Panasonic FV-0811RF1 disturb adjacent bedrooms during night use?

Acoustic measurement places Panasonic FV-0811RF1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Panasonic FV-0811RF1 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Panasonic FV-0811RF1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Panasonic FV-0811RF1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0811RF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0811RF1?

Panasonic FV-0811RF1 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0811RF1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0811RF1's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Panasonic FV-0811RF1 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0811RF1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories