Panasonic FV-0810RS2 Exhaust Fan Specifications

ENERGY STAR PD #2405526 · Bathroom/Utility Room · Qualified 2022-12-09
Verified Specification Summary

Rated for 100 CFM open-air (100.1 CFM at 0.25 in. w.g.), Panasonic FV-0810RS2 omits a published 0.1-inch sone rating and delivers 7.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 100 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0810RS2 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 100.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.6 CFM/W (#380/1,145)
Static Retention
100.1% @ 0.25"
Motor Draw
13.2 W (4.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0810RS2 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0810RS2 (EPA filing PD #2405526) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.1 CFM out of 100 CFM (100.1% retention, 12.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places FV-0810RS2 (series: Whisper Thin) (PD #2405526) among 92 Panasonic entries qualified through 2022-12-09. Lighting kit: No. At 7.6 CFM/W (#380 of 1,145, top 34.0% of 1,145 rated models, more efficient than 66.0% of rated models, 2.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.2 watts, about 4.8 kWh/yr (~$0.77/yr at $0.16/kWh) for 1 hr/day shower timers or 115.6 kWh/yr (~$18.50/yr) continuously. Closest competing matches include Delta ITG100 (100.0 CFM) and Utilitech 7131-04 (100.0 CFM).

How do flex elbows choke Panasonic FV-0810RS2 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Panasonic FV-0810RS2 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Panasonic FV-0810RS2 meet residential exhaust fan code specs?

Inspect Panasonic FV-0810RS2 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0810RS2 / Whisper Thin PD ID 2405526 (Qualified 2022-12-09)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (100.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Panasonic FV-0810RS2 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Panasonic FV-0810RS2 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0810RS2
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 100 sq ft1 CFM/sq ft @ 100.1 CFM
Tall Bath (9-ft Ceiling)Up to 88 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 50 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.8 kWh/yr (~$0.77/yr)13.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2115.6 kWh/yr (~$18.50/yr)13.2 W x 8,760 hrs / 1,000

Which competing models share Panasonic FV-0810RS2 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta ITG100 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter
Utilitech 7131-04 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter
Delta 100LED 100 / 75 CFM 1.5 sones 7.4 CFM/W 4 in. diameter
Delta GBR100LED 100 / 75 CFM 1.5 sones 7.4 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

How much airflow margin does Panasonic FV-0810RS2 give your bath?

Run a quick local room-volume check for Panasonic FV-0810RS2 by entering square footage and ceiling height to spot under-vented steam risks early.

Who should not install Panasonic FV-0810RS2 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Panasonic FV-0810RS2 for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 50 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 100 sq ft with 8-ft ceilings (88 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Panasonic FV-0810RS2?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic FV-0810RS2.

How does Panasonic FV-0810RS2 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Panasonic FV-0810RS2 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Panasonic FV-0810RS2?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Panasonic FV-0810RS2 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0810RS2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0810RS2?

Panasonic FV-0810RS2 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0810RS2's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0810RS2's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Panasonic FV-0810RS2 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0810RS2 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Panasonic FV-0810RS2 undersized or poorly matched for a bath renovation?

Skip Panasonic FV-0810RS2 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Panasonic FV-0810RS2 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Panasonic FV-0810RS2 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)