Skip to main content
Grant Estimator

Utilitech 7131-04 Exhaust Fan Specifications

ENERGY STAR PD #2684015 · Bathroom/Utility Room · Qualified 2023-10-13
Verified Specification Summary

Homeowners specifying Utilitech 7131-04 gain 100 CFM at 0.1 in. w.g. (88 CFM at 0.25 in. w.g.) where it registers #412 of 607 in quietness (1.5 sones) and delivers 7.6 CFM/W efficacy, venting bathrooms up to 88 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7131-04 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 88 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
7.6 CFM/W (#380/1,145)
Static Retention
88.0% @ 0.25"
Motor Draw
13.2 W (4.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Utilitech 7131-04 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 88 CFM out of 100 CFM (88.0% retention, 0.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2684015 verifies 7131-04 (series: Utilitech) under Utilitech (22 listed models, qualified 2023-10-13). Lighting kit: No. At 7.6 CFM/W (#380 of 1,145, top 34.0% of 1,145 rated models, more efficient than 66.0% of rated models, 2.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.2 watts, about 4.8 kWh/yr (~$0.77/yr at $0.16/kWh) for 1 hr/day shower timers or 115.6 kWh/yr (~$18.50/yr) continuously. Closest competing matches include Delta ITG100 (100.0 CFM) and Delta 100LED (100.0 CFM).

What acoustic percentile does Utilitech 7131-04 occupy among 1,145 bath blowers?

Inspect how Utilitech 7131-04 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Which exterior damper path suits Utilitech 7131-04 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Utilitech 7131-04 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Utilitech 7131-04 acoustic and static metrics stand?

Compare Utilitech 7131-04 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Utilitech (22 models) ENERGY STAR Certified Partner
Model Number & Series 7131-04 / Utilitech PD ID 2684015 (Qualified 2023-10-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (88 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Utilitech 7131-04 handle taller ceilings or walk-in tub steam?

Evaluate how Utilitech 7131-04 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Utilitech 7131-04
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 88 sq ft1 CFM/sq ft @ 88 CFM
Tall Bath (9-ft Ceiling)Up to 78 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 38 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.8 kWh/yr (~$0.77/yr)13.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2115.6 kWh/yr (~$18.50/yr)13.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Utilitech 7131-04?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta ITG100 100 / 88 CFM 1.5 sones (Same) 7.6 CFM/W 4 in. diameter
Delta 100LED 100 / 75 CFM 1.5 sones (Same) 7.4 CFM/W 4 in. diameter
Delta GBR100LED 100 / 75 CFM 1.5 sones (Same) 7.4 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter

Is Utilitech 7131-04 sized right for your shower or tub room?

Check whether Utilitech 7131-04 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does Utilitech 7131-04 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Utilitech 7131-04 for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 38 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 88 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Utilitech 7131-04?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Utilitech 7131-04.

How many kWh per year does Utilitech 7131-04 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Utilitech 7131-04 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Utilitech 7131-04 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7131-04's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Utilitech 7131-04?

Utilitech 7131-04 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Utilitech 7131-04's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7131-04's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Utilitech 7131-04 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7131-04 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Utilitech 7131-04 in a bathroom remodel?

Avoid specifying Utilitech 7131-04 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Utilitech 7131-04 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Utilitech 7131-04 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Utilitech 7131-04 occupy in EPA filings?

With 1.5 sones at 0.1 in. w.g., Utilitech 7131-04 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories