Homeowners specifying Anzzi EF-AZ107WH gain 100 CFM at 0.1 in. w.g. (92.2 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 3.9 CFM/W efficacy, venting bathrooms up to 92 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ107WH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 92.2 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 92.2% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Anzzi EF-AZ107WH vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 92.2 CFM out of 100 CFM (92.2% retention, 4.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Anzzi registers 8 certified models, with SKU EF-AZ107WH (series: EF) (PD #3425445) certified since 2024-03-15. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include ACIQ AP100 (100.0 CFM) and Air King FR100 (100.0 CFM).
What acoustic percentile does Anzzi EF-AZ107WH occupy among 1,145 bath blowers?
Inspect how Anzzi EF-AZ107WH positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Anzzi EF-AZ107WH best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Anzzi EF-AZ107WH housings.
Where do Anzzi EF-AZ107WH acoustic and static metrics stand?
Compare Anzzi EF-AZ107WH published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Anzzi (8 models) | ENERGY STAR Certified Partner |
| Model Number & Series | EF-AZ107WH / EF | PD ID 3425445 (Qualified 2024-03-15) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (92.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Anzzi EF-AZ107WH handle taller ceilings or walk-in tub steam?
Evaluate how Anzzi EF-AZ107WH scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Anzzi EF-AZ107WH?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AP100 | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Air King FR100 | 100 / 82.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Aria QBV01000 | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Cyclone CT100 | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7105-12-BN | 100 / 75.4 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
Is Anzzi EF-AZ107WH sized right for your shower or tub room?
Check whether Anzzi EF-AZ107WH clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
What plumbing or duct constraints rule out Anzzi EF-AZ107WH?
Compare where Anzzi EF-AZ107WH excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 42 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 92.2 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Anzzi EF-AZ107WH?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Anzzi EF-AZ107WH.
Is Anzzi EF-AZ107WH energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Anzzi EF-AZ107WH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ107WH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Anzzi EF-AZ107WH?
Anzzi EF-AZ107WH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Anzzi EF-AZ107WH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ107WH's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Anzzi EF-AZ107WH serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Anzzi EF-AZ107WH supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Anzzi EF-AZ107WH for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Anzzi EF-AZ107WH lacks adequate reserve.
How does Anzzi EF-AZ107WH handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Anzzi EF-AZ107WH yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Anzzi EF-AZ107WH quiet enough for a primary bedroom bathroom?
At 2.0 sones, Anzzi EF-AZ107WH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)