Certified by EPA ENERGY STAR, Air King LEDAK100 delivers 100 CFM free-air (83.3 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 83 sq ft (8-ft height) or 74 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King LEDAK100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 83.3 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
83.3% @ 0.25"
Motor Draw
26.3 W (9.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King LEDAK100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 83.3 CFM at 0.25 in. w.g. (83.3% retention, 4.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Air King's 62-unit lineup, LEDAK100 (series: Air King) carries PD #2269997 dating to 2016-06-15. Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.3 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 230.4 kWh/yr (~$36.86/yr) continuously. Closest competing matches include Panasonic FV-0810RS1 (100.0 CFM) and Panasonic FV-0811RF1 (100.0 CFM).

How noisy is Air King LEDAK100 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Air King LEDAK100 measures 2.0 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Why does rigid 4 in. diameter ducting protect Air King LEDAK100 airflow?

Connecting Air King LEDAK100 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Air King LEDAK100 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King LEDAK100 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series LEDAK100 / Air King PD ID 2269997 (Qualified 2016-06-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (83.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Air King LEDAK100?

Calculated coverage metrics translate Air King LEDAK100 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Air King LEDAK100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 83 sq ft1 CFM/sq ft @ 83.3 CFM
Tall Bath (9-ft Ceiling)Up to 74 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 33 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2230.4 kWh/yr (~$36.86/yr)26.3 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Air King LEDAK100?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic FV-0810RS1 100 / 89 CFM Unpublished 3.8 CFM/W 4 in. diameter
Panasonic FV-0811RF1 100 / 93.1 CFM Unpublished 3.8 CFM/W 3 in. diameter
Panasonic Eco Solutions FV-0810RSL1 100 / 90 CFM Unpublished 3.7 CFM/W 4 in. diameter
ACIQ AP100 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ107WH 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter

Does Air King LEDAK100 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King LEDAK100 percentage capacity without sending data.

Who should not install Air King LEDAK100 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Air King LEDAK100 for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 33 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 83.3 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Air King LEDAK100?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King LEDAK100.

How does Air King LEDAK100 sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, Air King LEDAK100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Air King LEDAK100?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Air King LEDAK100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King LEDAK100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King LEDAK100?

Air King LEDAK100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King LEDAK100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King LEDAK100's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Air King LEDAK100 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Air King LEDAK100 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Air King LEDAK100 undersized or poorly matched for a bath renovation?

Skip Air King LEDAK100 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Air King LEDAK100 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Air King LEDAK100 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories