Homeowners specifying Panasonic Eco Solutions FV-0810RSL1 gain 100 CFM at 0.1 in. w.g. (90 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 3.7 CFM/W efficacy, venting bathrooms up to 90 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic Eco Solutions FV-0810RSL1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 90 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.7 CFM/W (#987/1,145)
- Static Retention
- 90.0% @ 0.25"
- Motor Draw
- 27.0 W (9.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic Eco Solutions FV-0810RSL1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic Eco Solutions FV-0810RSL1 (EPA filing PD #2391572) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 90 CFM out of 100 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Panasonic Eco Solutions's 9-unit lineup, FV-0810RSL1 (series: Whisper Thin) carries PD #2391572 dating to 2022-01-21. Lighting kit: Yes. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.0 watts, about 9.9 kWh/yr (~$1.58/yr at $0.16/kWh) for 1 hr/day shower timers or 236.5 kWh/yr (~$37.84/yr) continuously. Closest competing matches include Hunter 90064A (100.0 CFM) and Hunter 90065A (100.0 CFM).
Which exterior damper path suits Panasonic Eco Solutions FV-0810RSL1 best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic Eco Solutions FV-0810RSL1 housings.
Where do Panasonic Eco Solutions FV-0810RSL1 acoustic and static metrics stand?
Compare Panasonic Eco Solutions FV-0810RSL1 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic Eco Solutions (9 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-0810RSL1 / Whisper Thin | PD ID 2391572 (Qualified 2022-01-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (90 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Panasonic Eco Solutions FV-0810RSL1 handle taller ceilings or walk-in tub steam?
Evaluate how Panasonic Eco Solutions FV-0810RSL1 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 90 sq ft | 1 CFM/sq ft @ 90 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 40 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.9 kWh/yr (~$1.58/yr) | 27.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 236.5 kWh/yr (~$37.84/yr) | 27.0 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Panasonic Eco Solutions FV-0810RSL1?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Hunter 90064A | 100 / 89.6 CFM | 1.5 sones | 3.9 CFM/W | 4 in. diameter |
| Hunter 90065A | 100 / 89.6 CFM | 1.5 sones | 3.9 CFM/W | 4 in. diameter |
| Anzzi EF-AZ106MB | 100 / 92.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Anzzi EF-AZ106WH | 100 / 92.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| Fantech SMPL100 (484302) | 100 / 91.2 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
Is Panasonic Eco Solutions FV-0810RSL1 sized right for your shower or tub room?
Check whether Panasonic Eco Solutions FV-0810RSL1 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Where should contractors skip Panasonic Eco Solutions FV-0810RSL1 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic Eco Solutions FV-0810RSL1 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 40 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 90 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Panasonic Eco Solutions FV-0810RSL1?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic Eco Solutions FV-0810RSL1.
How does Panasonic Eco Solutions FV-0810RSL1 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic Eco Solutions FV-0810RSL1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Panasonic Eco Solutions FV-0810RSL1?
Rule out Panasonic Eco Solutions FV-0810RSL1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Panasonic Eco Solutions FV-0810RSL1 capacity?
Because static drag at 0.25 in. w.g. lowers Panasonic Eco Solutions FV-0810RSL1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Panasonic Eco Solutions FV-0810RSL1 compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Panasonic Eco Solutions FV-0810RSL1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Panasonic Eco Solutions FV-0810RSL1 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Panasonic Eco Solutions FV-0810RSL1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Panasonic Eco Solutions FV-0810RSL1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic Eco Solutions FV-0810RSL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic Eco Solutions FV-0810RSL1?
Panasonic Eco Solutions FV-0810RSL1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic Eco Solutions FV-0810RSL1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic Eco Solutions FV-0810RSL1's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)