Certified by EPA ENERGY STAR, Ortech ODDSS-100-3HS delivers 100 CFM free-air (106.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 106 sq ft (8-ft height) or 94 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODDSS-100-3HS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 106.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.3 CFM/W (#258/1,145)
Static Retention
106.5% @ 0.25"
Motor Draw
10.8 W (3.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODDSS-100-3HS vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech ODDSS-100-3HS (EPA filing PD #4572797) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places ODDSS-100-3HS (series: ODDSS) (PD #4572797) among 27 Ortech entries qualified through 2026-02-11. Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

Why does rigid 4 in. diameter ducting protect Ortech ODDSS-100-3HS airflow?

Connecting Ortech ODDSS-100-3HS through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Ortech ODDSS-100-3HS performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODDSS-100-3HS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODDSS-100-3HS / ODDSS PD ID 4572797 (Qualified 2026-02-11)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (106.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Ortech ODDSS-100-3HS?

Calculated coverage metrics translate Ortech ODDSS-100-3HS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Ortech ODDSS-100-3HS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 106 sq ft1 CFM/sq ft @ 106.5 CFM
Tall Bath (9-ft Ceiling)Up to 94 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 56 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.9 kWh/yr (~$0.62/yr)10.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.294.6 kWh/yr (~$15.14/yr)10.8 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Ortech ODDSS-100-3HS?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Ortech ODDSS-100-3HS match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODDSS-100-3HS percentage capacity without sending data.

Where should contractors skip Ortech ODDSS-100-3HS on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Ortech ODDSS-100-3HS carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 56 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 106.5 CFM net static output
  • Works well for: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Ortech ODDSS-100-3HS?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODDSS-100-3HS.

Will long attic ducting choke Ortech ODDSS-100-3HS capacity?

Because static drag at 0.25 in. w.g. lowers Ortech ODDSS-100-3HS from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Ortech ODDSS-100-3HS compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Ortech ODDSS-100-3HS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Ortech ODDSS-100-3HS consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Ortech ODDSS-100-3HS draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Ortech ODDSS-100-3HS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODDSS-100-3HS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODDSS-100-3HS?

Ortech ODDSS-100-3HS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODDSS-100-3HS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODDSS-100-3HS's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Ortech ODDSS-100-3HS score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Ortech ODDSS-100-3HS delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Ortech ODDSS-100-3HS?

Rule out Ortech ODDSS-100-3HS when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories