Tested under HVI protocols, the Ortech ODDSS-100-3 exhaust unit achieves 100 CFM at 0.1 in. w.g. (106.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, covering standard baths up to 106 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODDSS-100-3 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 106.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.3 CFM/W (#258/1,145)
- Static Retention
- 106.5% @ 0.25"
- Motor Draw
- 10.8 W (3.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Ortech ODDSS-100-3 vs. 1,145-Model ENERGY STAR Benchmarks show?
Ortech ODDSS-100-3 (EPA filing PD #3555662) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Ortech maintains 27 active ENERGY STAR blowers; ODDSS-100-3 (series: ODDSS) (PD #3555662) gained qualification on 2024-07-19. Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).
What attic duct routing preserves Ortech ODDSS-100-3 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Ortech ODDSS-100-3, preventing premature peeling paint and mold growth.
How does Ortech ODDSS-100-3 measure up on airflow and noise ratings?
Each row below breaks down Ortech ODDSS-100-3 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ODDSS-100-3 / ODDSS | PD ID 3555662 (Qualified 2024-07-19) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (106.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Ortech ODDSS-100-3 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 94.6 kWh/yr (~$15.14/yr) | 10.8 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Ortech ODDSS-100-3?
Compare Ortech ODDSS-100-3 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100RLED | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Can you size Ortech ODDSS-100-3 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Ortech ODDSS-100-3 verified capacity.
Who should not install Ortech ODDSS-100-3 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Ortech ODDSS-100-3 for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 106.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around ENERGY STAR sones up to 106 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Ortech ODDSS-100-3?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Ortech ODDSS-100-3.
When is Ortech ODDSS-100-3 undersized or poorly matched for a bath renovation?
Skip Ortech ODDSS-100-3 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Ortech ODDSS-100-3 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Ortech ODDSS-100-3 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Ortech ODDSS-100-3 sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Ortech ODDSS-100-3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Ortech ODDSS-100-3?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Ortech ODDSS-100-3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODDSS-100-3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech ODDSS-100-3?
Ortech ODDSS-100-3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech ODDSS-100-3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODDSS-100-3's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Ortech ODDSS-100-3 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Ortech ODDSS-100-3 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)