Air King AK110PN Exhaust Fan Specifications

ENERGY STAR PD #2256893 · Bathroom/Utility Room · Qualified 2016-01-15
Verified Specification Summary

Certified by EPA ENERGY STAR, Air King AK110PN delivers 100 CFM free-air (83.8 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 83 sq ft (8-ft height) or 74 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK110PN Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 83.8 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
83.8% @ 0.25"
Motor Draw
26.3 W (9.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King AK110PN vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 83.8 CFM at 0.25 in. w.g. (83.8% retention, 3.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Air King AK110PN (series: N/A) under PD #2256893 (62 models registered, 2016-01-15). Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.3 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 230.4 kWh/yr (~$36.86/yr) continuously. Closest competing matches include Panasonic FV-0810RS1 (100.0 CFM) and Panasonic FV-0811RF1 (100.0 CFM).

How noisy is Air King AK110PN compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Air King AK110PN measures 2.0 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Why does rigid 4 in. diameter ducting protect Air King AK110PN airflow?

Connecting Air King AK110PN through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Air King AK110PN performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King AK110PN lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series AK110PN / N/A PD ID 2256893 (Qualified 2016-01-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (83.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Air King AK110PN?

Calculated coverage metrics translate Air King AK110PN airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Air King AK110PN
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 83 sq ft1 CFM/sq ft @ 83.8 CFM
Tall Bath (9-ft Ceiling)Up to 74 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 33 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2230.4 kWh/yr (~$36.86/yr)26.3 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Air King AK110PN?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic FV-0810RS1 100 / 89 CFM Unpublished 3.8 CFM/W 4 in. diameter
Panasonic FV-0811RF1 100 / 93.1 CFM Unpublished 3.8 CFM/W 3 in. diameter
Panasonic Eco Solutions FV-0810RSL1 100 / 90 CFM Unpublished 3.7 CFM/W 4 in. diameter
ACIQ AP100 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ107WH 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter

Does Air King AK110PN match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King AK110PN percentage capacity without sending data.

Where should contractors skip Air King AK110PN on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Air King AK110PN carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 33 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 83.8 CFM net static output
  • Works well for: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Air King AK110PN?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King AK110PN.

Will long attic ducting choke Air King AK110PN capacity?

Because static drag at 0.25 in. w.g. lowers Air King AK110PN from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Air King AK110PN compared with a standard 3.0 sone builder fan?

Tested at 2.0 sones, Air King AK110PN produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Air King AK110PN consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Air King AK110PN draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Air King AK110PN pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK110PN's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King AK110PN?

Air King AK110PN features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King AK110PN's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK110PN's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Air King AK110PN score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Air King AK110PN delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Air King AK110PN?

Rule out Air King AK110PN when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories