Certified by EPA ENERGY STAR, Delta SLM50-100D delivers 100 CFM free-air (101 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 101 sq ft (8-ft height) or 89 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM50-100D Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 101 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.7 CFM/W (#306/1,145)
- Static Retention
- 101.0% @ 0.25"
- Motor Draw
- 11.5 W (4.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta SLM50-100D vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta SLM50-100D (EPA filing PD #4008364) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 101 CFM out of 100 CFM (101.0% retention, 13.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places SLM50-100D (series: BreezSlim) (PD #4008364) among 121 Delta entries qualified through 2025-03-21. Lighting kit: No. At 8.7 CFM/W (#306 of 1,145, top 27.6% of 1,145 rated models, more efficient than 72.4% of rated models, 4.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).
Why does rigid 4 in. diameter ducting protect Delta SLM50-100D airflow?
Connecting Delta SLM50-100D through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Delta SLM50-100D performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM50-100D lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SLM50-100D / BreezSlim | PD ID 4008364 (Qualified 2025-03-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (101 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Delta SLM50-100D?
Calculated coverage metrics translate Delta SLM50-100D airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 101 sq ft | 1 CFM/sq ft @ 101 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 51 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 100.7 kWh/yr (~$16.11/yr) | 11.5 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Delta SLM50-100D?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-MB | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-03 | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Does Delta SLM50-100D match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM50-100D percentage capacity without sending data.
Where should contractors skip Delta SLM50-100D on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta SLM50-100D carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 51 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 101 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Delta SLM50-100D?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM50-100D.
How loud is Delta SLM50-100D compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Delta SLM50-100D produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Delta SLM50-100D consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Delta SLM50-100D draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Delta SLM50-100D pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM50-100D's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SLM50-100D?
Delta SLM50-100D features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SLM50-100D's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM50-100D's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Delta SLM50-100D score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta SLM50-100D delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Delta SLM50-100D?
Rule out Delta SLM50-100D when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Delta SLM50-100D capacity?
Because static drag at 0.25 in. w.g. lowers Delta SLM50-100D from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)