Skip to main content
Grant Estimator

Delta VFB25ADBT Exhaust Fan Specifications

ENERGY STAR PD #2272571 · Bathroom/Utility Room · Qualified 2016-07-15
Verified Specification Summary

The Delta VFB25ADBT (BreezSignature) moves 110 CFM at 0.1 in. w.g. (81.3 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 7.9 CFM/W efficacy, sizing bathrooms up to 81 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta VFB25ADBT Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 81.3 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
7.9 CFM/W (#356/1,145)
Static Retention
73.9% @ 0.25"
Motor Draw
13.9 W (5.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta VFB25ADBT vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 81.3 CFM at 0.25 in. w.g. (73.9% retention, 13.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta VFB25ADBT (series: BreezSignature) under PD #2272571 (121 models registered, 2016-07-15). Lighting kit: No. At 7.9 CFM/W (#356 of 1,145, top 31.8% of 1,145 rated models, more efficient than 68.2% of rated models, 3.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.9 watts, about 5.1 kWh/yr (~$0.82/yr at $0.16/kWh) for 1 hr/day shower timers or 121.8 kWh/yr (~$19.49/yr) continuously. Closest competing matches include Panasonic RG-S100A (100.0 CFM) and Panasonic Eco Solutions RG-N110LHA (110.0 CFM).

Where does Delta VFB25ADBT sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

How does duct geometry alter Delta VFB25ADBT static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Delta VFB25ADBT?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta VFB25ADBT alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series VFB25ADBT / BreezSignature PD ID 2272571 (Qualified 2016-07-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (81.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Delta VFB25ADBT ventilate safely?

Sizing outputs below convert Delta VFB25ADBT tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Delta VFB25ADBT
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 81 sq ft1 CFM/sq ft @ 81.3 CFM
Tall Bath (9-ft Ceiling)Up to 72 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 31 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.1 kWh/yr (~$0.82/yr)13.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2121.8 kWh/yr (~$19.49/yr)13.9 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Delta VFB25ADBT closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic RG-S100A 100 / 100.1 CFM 1.1 sones (+0.10) 7.6 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-N110LHA 110 / 111.2 CFM 1.1 sones (+0.10) 9.5 CFM/W 4 in. diameter
Delta 110F 110 / 81.3 CFM 1.0 sones (Same) 7.9 CFM/W 4 in. diameter
HomeWerks Worldwide 7130-40-BT 90 / 84.3 CFM 1.2 sones (+0.20) 7.7 CFM/W 4 in. diameter
Greenheck SP-A125 109 / N/A CFM 0.7 sones (-0.30) 5.8 CFM/W 6 x 8 in. rectangular

Will Delta VFB25ADBT clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Delta VFB25ADBT satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Does Delta VFB25ADBT suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta VFB25ADBT for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 31 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 81 sq ft with 8-ft ceilings (72 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Delta VFB25ADBT?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta VFB25ADBT.

Does Delta VFB25ADBT pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta VFB25ADBT easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Delta VFB25ADBT in a bathroom remodel?

Avoid specifying Delta VFB25ADBT in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Delta VFB25ADBT airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta VFB25ADBT achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Delta VFB25ADBT occupy in EPA filings?

With 1.0 sones at 0.1 in. w.g., Delta VFB25ADBT operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Delta VFB25ADBT add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Delta VFB25ADBT averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Delta VFB25ADBT pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta VFB25ADBT's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta VFB25ADBT?

Delta VFB25ADBT features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta VFB25ADBT's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta VFB25ADBT's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories