Skip to main content
Grant Estimator

KOHLER 34457-NA Exhaust Fan Specifications

ENERGY STAR PD #4528856 · Bathroom/Utility Room · Qualified 2026-01-28
Verified Specification Summary

The KOHLER 34457-NA (34457) moves 130 CFM at 0.1 in. w.g. (103.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 3.7 CFM/W efficacy, sizing bathrooms up to 103 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34457-NA Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / 103.7 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.7 CFM/W (#987/1,145)
Static Retention
79.8% @ 0.25"
Motor Draw
35.1 W (12.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does KOHLER 34457-NA vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER 34457-NA (EPA filing PD #4528856) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 130 CFM open-air to 103.7 CFM at 0.25 in. w.g. (79.8% retention, 7.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 34457-NA (series: 34457) (PD #4528856) among 32 KOHLER entries qualified through 2026-01-28. Lighting kit: Yes. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.1 watts, about 12.8 kWh/yr (~$2.05/yr at $0.16/kWh) for 1 hr/day shower timers or 307.5 kWh/yr (~$49.20/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).

How does duct geometry alter KOHLER 34457-NA static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to KOHLER 34457-NA?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for KOHLER 34457-NA alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share KOHLER (32 models) ENERGY STAR Certified Partner
Model Number & Series 34457-NA / 34457 PD ID 4528856 (Qualified 2026-01-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (103.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can KOHLER 34457-NA ventilate safely?

Sizing outputs below convert KOHLER 34457-NA tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for KOHLER 34457-NA
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 103 sq ft1 CFM/sq ft @ 103.7 CFM
Tall Bath (9-ft Ceiling)Up to 92 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 53 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)12.8 kWh/yr (~$2.05/yr)35.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2307.5 kWh/yr (~$49.20/yr)35.1 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match KOHLER 34457-NA closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter
Greenheck SP-B110ES 118 / 100 CFM 1.5 sones 4.0 CFM/W 6 in. diameter
KORA SBF110N 119.2 / N/A CFM 1.6 sones 3.5 CFM/W 4 in. diameter

Will KOHLER 34457-NA clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether KOHLER 34457-NA satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Where should contractors skip KOHLER 34457-NA on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for KOHLER 34457-NA carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 53 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 103 sq ft with 8-ft ceilings (92 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern KOHLER 34457-NA?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting KOHLER 34457-NA.

How does KOHLER 34457-NA score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), KOHLER 34457-NA delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify KOHLER 34457-NA?

Rule out KOHLER 34457-NA when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke KOHLER 34457-NA capacity?

Because static drag at 0.25 in. w.g. lowers KOHLER 34457-NA from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is KOHLER 34457-NA compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, KOHLER 34457-NA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does KOHLER 34457-NA consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, KOHLER 34457-NA draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can KOHLER 34457-NA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34457-NA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing KOHLER 34457-NA?

KOHLER 34457-NA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change KOHLER 34457-NA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34457-NA's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories