In EPA dataset 8dv7-nngq, KOHLER K-34457 tests at 130 CFM free discharge (103.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 3.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 103 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER K-34457 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 103.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.7 CFM/W (#987/1,145)
- Static Retention
- 79.8% @ 0.25"
- Motor Draw
- 35.1 W (12.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does KOHLER K-34457 vs. 1,145-Model ENERGY STAR Benchmarks show?
KOHLER K-34457 (EPA filing PD #4528860) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 130 CFM open-air to 103.7 CFM at 0.25 in. w.g. (79.8% retention, 7.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
KOHLER maintains 32 active ENERGY STAR blowers; K-34457 (series: 34457) (PD #4528860) gained qualification on 2026-01-28. Lighting kit: Yes. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.1 watts, about 12.8 kWh/yr (~$2.05/yr at $0.16/kWh) for 1 hr/day shower timers or 307.5 kWh/yr (~$49.20/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).
Why avoid unvented attic termination with KOHLER K-34457?
Under ASHRAE 62.2 best practice, KOHLER K-34457 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern KOHLER K-34457?
Before cutting ceiling drywall or sizing attic transitions for KOHLER K-34457, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | KOHLER (32 models) | ENERGY STAR Certified Partner |
| Model Number & Series | K-34457 / 34457 | PD ID 4528860 (Qualified 2026-01-28) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (103.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit KOHLER K-34457?
Bathroom ventilation sizing below maps KOHLER K-34457 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.8 kWh/yr (~$2.05/yr) | 35.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 307.5 kWh/yr (~$49.20/yr) | 35.1 W x 8,760 hrs / 1,000 |
What peer models sit nearest KOHLER K-34457 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to KOHLER K-34457.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| Greenheck SP-B110ES | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| KORA SBF110N | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |
What percentage of room demand does KOHLER K-34457 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against KOHLER K-34457 tested delivery.
Where should contractors skip KOHLER K-34457 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for KOHLER K-34457 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 103.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 103 sq ft
- Works well for: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for KOHLER K-34457?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing KOHLER K-34457.
Will long attic ducting choke KOHLER K-34457 capacity?
Because static drag at 0.25 in. w.g. lowers KOHLER K-34457 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is KOHLER K-34457 compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, KOHLER K-34457 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does KOHLER K-34457 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, KOHLER K-34457 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can KOHLER K-34457 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER K-34457's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing KOHLER K-34457?
KOHLER K-34457 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change KOHLER K-34457's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER K-34457's safe coverage footprint from 50 sq ft to 44 sq ft.
How does KOHLER K-34457 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), KOHLER K-34457 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify KOHLER K-34457?
Rule out KOHLER K-34457 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)