The Nutone PEN811 (FLEX SERIES) moves 110 CFM at 0.1 in. w.g. (94.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 4.2 CFM/W efficacy, sizing bathrooms up to 94 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone PEN811 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 94.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 85.5% @ 0.25"
- Motor Draw
- 26.2 W (9.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Nutone PEN811 vs. 1,145-Model ENERGY STAR Benchmarks show?
Nutone PEN811 (EPA filing PD #3550174) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.1 CFM out of 110 CFM (85.5% retention, 2.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Nutone registers 16 certified models, with SKU PEN811 (series: FLEX SERIES) (PD #3550174) certified since 2024-04-12. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).
How does duct geometry alter Nutone PEN811 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Nutone PEN811?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Nutone PEN811 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Nutone (16 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PEN811 / FLEX SERIES | PD ID 3550174 (Qualified 2024-04-12) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (94.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Nutone PEN811 ventilate safely?
Sizing outputs below convert Nutone PEN811 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Nutone PEN811 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Broan AER110LTW | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Broan 791LEDM | 110 / 93.4 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT14-24OD-H | 110 / 98.1 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
Will Nutone PEN811 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Nutone PEN811 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Which bath layouts should avoid specifying Nutone PEN811?
Match Nutone PEN811 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 44 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 94 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Nutone PEN811?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Nutone PEN811.
Where does Nutone PEN811 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Nutone PEN811.
What happens to Nutone PEN811 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Nutone PEN811 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Nutone PEN811 sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Nutone PEN811 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Nutone PEN811 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Nutone PEN811 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Nutone PEN811 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone PEN811's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Nutone PEN811?
Nutone PEN811 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Nutone PEN811's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone PEN811's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Nutone PEN811 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Nutone PEN811 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)