The Ortech ODC-9006 (OFC-9006) moves 90 CFM at 0.1 in. w.g. (73.4 CFM at 0.25 in. w.g.), registers #107 of 607 in quietness (0.6 sones), and delivers 5.6 CFM/W efficacy, sizing bathrooms up to 73 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODC-9006 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 73.4 CFM
- Noise @ 0.1"
- 0.6 sones (#107/607)
- Efficacy Rank
- 5.6 CFM/W (#470/1,145)
- Static Retention
- 81.6% @ 0.25"
- Motor Draw
- 16.1 W (5.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Ortech ODC-9006 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 90 CFM open-air to 73.4 CFM at 0.25 in. w.g. (81.6% retention, 6.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3892190 verifies ODC-9006 (series: OFC-9006) under Ortech (27 listed models, qualified 2024-12-20). Lighting kit: No. At 5.6 CFM/W (#470 of 1,145, top 41.0% of 1,145 rated models, more efficient than 59.0% of rated models, 0.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.1 watts, about 5.9 kWh/yr (~$0.94/yr at $0.16/kWh) for 1 hr/day shower timers or 141.0 kWh/yr (~$22.56/yr) continuously. Closest competing matches include ACIQ ANP80 (80.0 CFM) and Anzzi EF-AZ101WH (80.0 CFM).
Where does Ortech ODC-9006 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.6 sones against all 1,145 EPA listings.
How does duct geometry alter Ortech ODC-9006 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Ortech ODC-9006?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Ortech ODC-9006 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ODC-9006 / OFC-9006 | PD ID 3892190 (Qualified 2024-12-20) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (73.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.6 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Ortech ODC-9006 ventilate safely?
Sizing outputs below convert Ortech ODC-9006 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 73 sq ft | 1 CFM/sq ft @ 73.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 65 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 23 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.9 kWh/yr (~$0.94/yr) | 16.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 141.0 kWh/yr (~$22.56/yr) | 16.1 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Ortech ODC-9006 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ ANP80 | 80 / 62.6 CFM | 0.6 sones (Same) | 4.9 CFM/W | 4 in. diameter |
| Anzzi EF-AZ101WH | 80 / 68.9 CFM | 0.7 sones (+0.10) | 5.3 CFM/W | 4 in. diameter |
| Aria QBV0800 | 80 / 68.9 CFM | 0.7 sones (+0.10) | 5.3 CFM/W | 4 in. diameter |
| Haier QVE801DTWW | 80 / 68.9 CFM | 0.7 sones (+0.10) | 5.3 CFM/W | 4 in. diameter |
| Dayton 3DPE4B | 90 / N/A CFM | 0.4 sones (-0.20) | 5.5 CFM/W | 6 in. diameter |
Will Ortech ODC-9006 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Ortech ODC-9006 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Where should contractors skip Ortech ODC-9006 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Ortech ODC-9006 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 23 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 73 sq ft with 8-ft ceilings (65 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Ortech ODC-9006?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Ortech ODC-9006.
How loud is Ortech ODC-9006 compared with a standard 3.0 sone builder fan?
Tested at 0.6 sones, Ortech ODC-9006 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Ortech ODC-9006 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Ortech ODC-9006 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Ortech ODC-9006 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODC-9006's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech ODC-9006?
Ortech ODC-9006 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech ODC-9006's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODC-9006's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Ortech ODC-9006 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Ortech ODC-9006 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Ortech ODC-9006?
Rule out Ortech ODC-9006 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Ortech ODC-9006 capacity?
Because static drag at 0.25 in. w.g. lowers Ortech ODC-9006 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)