Certified by EPA ENERGY STAR, Broan AE50=HPIVFNwithAE50F delivers 50 CFM free-air (51.9 CFM at 0.25 in. w.g.) and registers #83 of 607 in quietness (0.5 sones) and delivers 3.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 51 sq ft (8-ft height) or 46 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50=HPIVFNwithAE50F Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 51.9 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 3.5 CFM/W (#1,038/1,145)
- Static Retention
- 103.8% @ 0.25"
- Motor Draw
- 14.3 W (5.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE50=HPIVFNwithAE50F vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.9 CFM out of 50 CFM (103.8% retention, 16.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Broan registers 207 certified models, with SKU AE50=HPIVFNwithAE50F (series: InVent) (PD #2271830) certified since 2016-07-01. Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.3 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 125.3 kWh/yr (~$20.05/yr) continuously. Closest competing matches include Air King AK50S (50.0 CFM) and Air King FR50 (50.0 CFM).
How noisy is Broan AE50=HPIVFNwithAE50F compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan AE50=HPIVFNwithAE50F measures 0.5 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Broan AE50=HPIVFNwithAE50F airflow?
Connecting Broan AE50=HPIVFNwithAE50F through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan AE50=HPIVFNwithAE50F performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan AE50=HPIVFNwithAE50F lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE50=HPIVFNwithAE50F / InVent | PD ID 2271830 (Qualified 2016-07-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (51.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan AE50=HPIVFNwithAE50F?
Calculated coverage metrics translate Broan AE50=HPIVFNwithAE50F airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 46 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 125.3 kWh/yr (~$20.05/yr) | 14.3 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan AE50=HPIVFNwithAE50F?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King AK50S | 50 / 41.1 CFM | 0.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Air King FR50 | 50 / 42 CFM | 0.6 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
| Ortech ODE-5004 | 50 / 43.6 CFM | 0.4 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| ACIQ AP50 | 50 / 42.3 CFM | 0.4 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| ACIQ ANP50 | 50 / 42.3 CFM | 0.4 sones (-0.10) | 4.0 CFM/W | 4 in. diameter |
Does Broan AE50=HPIVFNwithAE50F match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan AE50=HPIVFNwithAE50F percentage capacity without sending data.
Where should contractors skip Broan AE50=HPIVFNwithAE50F on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan AE50=HPIVFNwithAE50F carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 51.9 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan AE50=HPIVFNwithAE50F?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan AE50=HPIVFNwithAE50F.
Will long attic ducting choke Broan AE50=HPIVFNwithAE50F capacity?
Because static drag at 0.25 in. w.g. lowers Broan AE50=HPIVFNwithAE50F from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Broan AE50=HPIVFNwithAE50F compared with a standard 3.0 sone builder fan?
Tested at 0.5 sones, Broan AE50=HPIVFNwithAE50F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Broan AE50=HPIVFNwithAE50F consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan AE50=HPIVFNwithAE50F draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan AE50=HPIVFNwithAE50F pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50=HPIVFNwithAE50F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE50=HPIVFNwithAE50F?
Broan AE50=HPIVFNwithAE50F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE50=HPIVFNwithAE50F's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50=HPIVFNwithAE50F's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan AE50=HPIVFNwithAE50F score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan AE50=HPIVFNwithAE50F delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Broan AE50=HPIVFNwithAE50F?
Rule out Broan AE50=HPIVFNwithAE50F when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)