Broan AE50=A000HFwithAE50F Exhaust Fan Specifications

ENERGY STAR PD #2248771 · Bathroom/Utility Room · Qualified 2015-09-01
Verified Specification Summary

Tested under HVI protocols, the Broan AE50=A000HFwithAE50F exhaust unit achieves 50 CFM at 0.1 in. w.g. (51.9 CFM at 0.25 in. w.g.), registers #83 of 607 in quietness (0.5 sones) and delivers 3.5 CFM/W efficacy, covering standard baths up to 51 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50=A000HFwithAE50F Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 51.9 CFM
Noise @ 0.1"
0.5 sones (#83/607)
Efficacy Rank
3.5 CFM/W (#1,038/1,145)
Static Retention
103.8% @ 0.25"
Motor Draw
14.3 W (5.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE50=A000HFwithAE50F vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 51.9 CFM out of 50 CFM (103.8% retention, 16.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan maintains 207 active ENERGY STAR blowers; AE50=A000HFwithAE50F (series: Invent) (PD #2248771) gained qualification on 2015-09-01. Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.3 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 125.3 kWh/yr (~$20.05/yr) continuously. Closest competing matches include Air King AK50S (50.0 CFM) and Air King FR50 (50.0 CFM).

Where do Broan AE50=A000HFwithAE50F sones rank across EPA ENERGY STAR fans?

Comparing Broan AE50=A000HFwithAE50F (0.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.5 sone: 0.5 sones (17th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.5 sone: 0.5 sones (P17)

What attic duct routing preserves Broan AE50=A000HFwithAE50F CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan AE50=A000HFwithAE50F, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan AE50=A000HFwithAE50F measure up on airflow and noise ratings?

Each row below breaks down Broan AE50=A000HFwithAE50F certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE50=A000HFwithAE50F / Invent PD ID 2248771 (Qualified 2015-09-01)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (51.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan AE50=A000HFwithAE50F CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan AE50=A000HFwithAE50F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 51 sq ft1 CFM/sq ft @ 51.9 CFM
Tall Bath (9-ft Ceiling)Up to 46 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.2 kWh/yr (~$0.83/yr)14.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2125.3 kWh/yr (~$20.05/yr)14.3 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan AE50=A000HFwithAE50F?

Compare Broan AE50=A000HFwithAE50F side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Air King AK50S 50 / 41.1 CFM 0.5 sones (Same) 4.1 CFM/W 4 in. diameter
Air King FR50 50 / 42 CFM 0.6 sones (+0.10) 3.5 CFM/W 4 in. diameter
Ortech ODE-5004 50 / 43.6 CFM 0.4 sones (-0.10) 3.4 CFM/W 4 in. diameter
ACIQ AP50 50 / 42.3 CFM 0.4 sones (-0.10) 3.3 CFM/W 4 in. diameter
ACIQ ANP50 50 / 42.3 CFM 0.4 sones (-0.10) 4.0 CFM/W 4 in. diameter

Can you size Broan AE50=A000HFwithAE50F for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan AE50=A000HFwithAE50F verified capacity.

What plumbing or duct constraints rule out Broan AE50=A000HFwithAE50F?

Compare where Broan AE50=A000HFwithAE50F excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 51.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 0.5 sones up to 51 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Broan AE50=A000HFwithAE50F?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan AE50=A000HFwithAE50F.

Is Broan AE50=A000HFwithAE50F quiet enough for a primary bedroom bathroom?

At 0.5 sones, Broan AE50=A000HFwithAE50F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Broan AE50=A000HFwithAE50F energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Broan AE50=A000HFwithAE50F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50=A000HFwithAE50F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE50=A000HFwithAE50F?

Broan AE50=A000HFwithAE50F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE50=A000HFwithAE50F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50=A000HFwithAE50F's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Broan AE50=A000HFwithAE50F serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan AE50=A000HFwithAE50F supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Broan AE50=A000HFwithAE50F for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE50=A000HFwithAE50F lacks adequate reserve.

How does Broan AE50=A000HFwithAE50F handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE50=A000HFwithAE50F yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.