Skip to main content
Grant Estimator

Panasonic FV-1115VKL3 Exhaust Fan Specifications

ENERGY STAR PD #3477591 · Bathroom/Utility Room · Qualified 2024-05-03
Verified Specification Summary

Homeowners specifying Panasonic FV-1115VKL3 gain 150 CFM at 0.1 in. w.g. (152.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 12.2 CFM/W efficacy, venting bathrooms up to 152 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-1115VKL3 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 152.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
12.2 CFM/W (#76/1,145)
Static Retention
101.4% @ 0.25"
Motor Draw
12.3 W (4.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-1115VKL3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-1115VKL3 (EPA filing PD #3477591) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 152.1 CFM out of 150 CFM (101.4% retention, 13.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places FV-1115VKL3 (series: Whisper Green Select) (PD #3477591) among 92 Panasonic entries qualified through 2024-05-03. Lighting kit: Yes. At 12.2 CFM/W (#76 of 1,145, top 6.7% of 1,145 rated models, more efficient than 93.3% of rated models, 7.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.3 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 107.7 kWh/yr (~$17.23/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Fantech S110-130-150 (484315) (150.0 CFM).

Which exterior damper path suits Panasonic FV-1115VKL3 best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Panasonic FV-1115VKL3 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Panasonic FV-1115VKL3 acoustic and static metrics stand?

Compare Panasonic FV-1115VKL3 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-1115VKL3 / Whisper Green Select PD ID 3477591 (Qualified 2024-05-03)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (152.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Panasonic FV-1115VKL3 handle taller ceilings or walk-in tub steam?

Evaluate how Panasonic FV-1115VKL3 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Panasonic FV-1115VKL3
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 152 sq ft1 CFM/sq ft @ 152.1 CFM
Tall Bath (9-ft Ceiling)Up to 135 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 102 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.5 kWh/yr (~$0.72/yr)12.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2107.7 kWh/yr (~$17.23/yr)12.3 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Panasonic FV-1115VKL3?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Fantech S110-130-150 (484315) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech S110-130-150L (484316) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150H (484317) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150LH (484318) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter

Is Panasonic FV-1115VKL3 sized right for your shower or tub room?

Check whether Panasonic FV-1115VKL3 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does Panasonic FV-1115VKL3 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-1115VKL3 for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 102 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 152.1 CFM net static output
  • Best application: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Panasonic FV-1115VKL3?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic FV-1115VKL3.

Who should NOT install Panasonic FV-1115VKL3 in a bathroom remodel?

Avoid specifying Panasonic FV-1115VKL3 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Panasonic FV-1115VKL3 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-1115VKL3 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Panasonic FV-1115VKL3 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-1115VKL3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Panasonic FV-1115VKL3 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Panasonic FV-1115VKL3 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Panasonic FV-1115VKL3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-1115VKL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-1115VKL3?

Panasonic FV-1115VKL3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-1115VKL3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-1115VKL3's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Panasonic FV-1115VKL3 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-1115VKL3 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories