Homeowners specifying Fantech SC110-130-150LH (484318) gain 150 CFM at 0.1 in. w.g. (150 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 12.9 CFM/W efficacy, venting bathrooms up to 150 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SC110-130-150LH (484318) Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 150 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 12.9 CFM/W (#54/1,145)
- Static Retention
- 100.0% @ 0.25"
- Motor Draw
- 11.6 W (4.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Fantech SC110-130-150LH (484318) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech SC110-130-150LH (484318) (EPA filing PD #2507879) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 150 CFM out of 150 CFM (100.0% retention, 12.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Fantech maintains 52 active ENERGY STAR blowers; SC110-130-150LH (484318) (series: bathfan Select) (PD #2507879) gained qualification on 2023-05-19. Lighting kit: Yes. At 12.9 CFM/W (#54 of 1,145, top 5.2% of 1,145 rated models, more efficient than 94.8% of rated models, 8.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Panasonic FV-1115VQ1 (150.0 CFM).
Which exterior damper path suits Fantech SC110-130-150LH (484318) best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Fantech SC110-130-150LH (484318) housings.
Where do Fantech SC110-130-150LH (484318) acoustic and static metrics stand?
Compare Fantech SC110-130-150LH (484318) published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SC110-130-150LH (484318) / bathfan Select | PD ID 2507879 (Qualified 2023-05-19) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Fantech SC110-130-150LH (484318) handle taller ceilings or walk-in tub steam?
Evaluate how Fantech SC110-130-150LH (484318) scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 101.6 kWh/yr (~$16.26/yr) | 11.6 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Fantech SC110-130-150LH (484318)?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Panasonic FV-1115VQ1 | 150 / 154.7 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| Panasonic FV-1115VKL3 | 150 / 152.1 CFM | Unpublished | 12.2 CFM/W | 6 in. diameter |
| Panasonic FV-1115VKL3 with FV-VS15VK1 | 150 / 152.1 CFM | Unpublished | 12.2 CFM/W | 6 in. diameter |
| Panasonic FV-1115VK3 | 150 / 158.7 CFM | Unpublished | 13.7 CFM/W | 6 in. diameter |
Is Fantech SC110-130-150LH (484318) sized right for your shower or tub room?
Check whether Fantech SC110-130-150LH (484318) clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Does Fantech SC110-130-150LH (484318) suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech SC110-130-150LH (484318) for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 100 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 150 CFM net static output
- Best application: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for Fantech SC110-130-150LH (484318)?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Fantech SC110-130-150LH (484318).
Does duct resistance cut Fantech SC110-130-150LH (484318) airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech SC110-130-150LH (484318) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Fantech SC110-130-150LH (484318) occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech SC110-130-150LH (484318) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Fantech SC110-130-150LH (484318) add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Fantech SC110-130-150LH (484318) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Fantech SC110-130-150LH (484318) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SC110-130-150LH (484318)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech SC110-130-150LH (484318)?
Fantech SC110-130-150LH (484318) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech SC110-130-150LH (484318)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SC110-130-150LH (484318)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Fantech SC110-130-150LH (484318) pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech SC110-130-150LH (484318) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Fantech SC110-130-150LH (484318) in a bathroom remodel?
Avoid specifying Fantech SC110-130-150LH (484318) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)