Tested under HVI protocols, the Fantech SC110-130-150LHO (484319) exhaust unit achieves 150 CFM at 0.1 in. w.g. (150 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 12.9 CFM/W efficacy, covering standard baths up to 150 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SC110-130-150LHO (484319) Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 150 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 12.9 CFM/W (#54/1,145)
- Static Retention
- 100.0% @ 0.25"
- Motor Draw
- 11.6 W (4.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Fantech SC110-130-150LHO (484319) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech SC110-130-150LHO (484319) (EPA filing PD #2507880) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 150 CFM out of 150 CFM (100.0% retention, 12.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places SC110-130-150LHO (484319) (series: bathfan Select) (PD #2507880) among 52 Fantech entries qualified through 2023-05-19. Lighting kit: Yes. At 12.9 CFM/W (#54 of 1,145, top 5.2% of 1,145 rated models, more efficient than 94.8% of rated models, 8.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Panasonic FV-1115VQ1 (150.0 CFM).
What attic duct routing preserves Fantech SC110-130-150LHO (484319) CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Fantech SC110-130-150LHO (484319), preventing premature peeling paint and mold growth.
How does Fantech SC110-130-150LHO (484319) measure up on airflow and noise ratings?
Each row below breaks down Fantech SC110-130-150LHO (484319) certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SC110-130-150LHO (484319) / bathfan Select | PD ID 2507880 (Qualified 2023-05-19) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Fantech SC110-130-150LHO (484319) CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 101.6 kWh/yr (~$16.26/yr) | 11.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Fantech SC110-130-150LHO (484319)?
Compare Fantech SC110-130-150LHO (484319) side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Panasonic FV-1115VQ1 | 150 / 154.7 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| Panasonic FV-1115VKL3 | 150 / 152.1 CFM | Unpublished | 12.2 CFM/W | 6 in. diameter |
| Panasonic FV-1115VKL3 with FV-VS15VK1 | 150 / 152.1 CFM | Unpublished | 12.2 CFM/W | 6 in. diameter |
| Panasonic FV-1115VK3 | 150 / 158.7 CFM | Unpublished | 13.7 CFM/W | 6 in. diameter |
Can you size Fantech SC110-130-150LHO (484319) for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Fantech SC110-130-150LHO (484319) verified capacity.
Which bath layouts should avoid specifying Fantech SC110-130-150LHO (484319)?
Match Fantech SC110-130-150LHO (484319) directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 150 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around ENERGY STAR sones up to 150 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Fantech SC110-130-150LHO (484319)?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Fantech SC110-130-150LHO (484319).
What bathroom square footage can Fantech SC110-130-150LHO (484319) ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Fantech SC110-130-150LHO (484319) covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Fantech SC110-130-150LHO (484319) run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Fantech SC110-130-150LHO (484319).
What happens to Fantech SC110-130-150LHO (484319) CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Fantech SC110-130-150LHO (484319) moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Fantech SC110-130-150LHO (484319) sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Fantech SC110-130-150LHO (484319) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Fantech SC110-130-150LHO (484319) cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Fantech SC110-130-150LHO (484319) 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Fantech SC110-130-150LHO (484319) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SC110-130-150LHO (484319)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech SC110-130-150LHO (484319)?
Fantech SC110-130-150LHO (484319) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech SC110-130-150LHO (484319)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SC110-130-150LHO (484319)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)