Panasonic FV-1115VQ1 Exhaust Fan Specifications

ENERGY STAR PD #2337780 · Bathroom/Utility Room · Qualified 2019-05-03
Verified Specification Summary

Tested under HVI protocols, the Panasonic FV-1115VQ1 exhaust unit achieves 150 CFM at 0.1 in. w.g. (154.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 12.9 CFM/W efficacy, covering standard baths up to 154 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-1115VQ1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 154.7 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
12.9 CFM/W (#54/1,145)
Static Retention
103.1% @ 0.25"
Motor Draw
11.6 W (4.2 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-1115VQ1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-1115VQ1 (EPA filing PD #2337780) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 154.7 CFM out of 150 CFM (103.1% retention, 15.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2337780 verifies FV-1115VQ1 (series: WhisperCeiling DC) under Panasonic (92 listed models, qualified 2019-05-03). Lighting kit: No. At 12.9 CFM/W (#54 of 1,145, top 5.2% of 1,145 rated models, more efficient than 94.8% of rated models, 8.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Fantech S110-130-150 (484315) (150.0 CFM).

What attic duct routing preserves Panasonic FV-1115VQ1 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic FV-1115VQ1, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Panasonic FV-1115VQ1 measure up on airflow and noise ratings?

Each row below breaks down Panasonic FV-1115VQ1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-1115VQ1 / WhisperCeiling DC PD ID 2337780 (Qualified 2019-05-03)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (154.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Panasonic FV-1115VQ1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic FV-1115VQ1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 154 sq ft1 CFM/sq ft @ 154.7 CFM
Tall Bath (9-ft Ceiling)Up to 137 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 104 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.2 kWh/yr (~$0.67/yr)11.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2101.6 kWh/yr (~$16.26/yr)11.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Panasonic FV-1115VQ1?

Compare Panasonic FV-1115VQ1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Fantech S110-130-150 (484315) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech S110-130-150L (484316) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150H (484317) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150LH (484318) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter

Can you size Panasonic FV-1115VQ1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic FV-1115VQ1 verified capacity.

Which bath layouts should avoid specifying Panasonic FV-1115VQ1?

Match Panasonic FV-1115VQ1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 154.7 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 154 sq ft
  • Optimal use: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Panasonic FV-1115VQ1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic FV-1115VQ1.

What bathroom square footage can Panasonic FV-1115VQ1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-1115VQ1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Panasonic FV-1115VQ1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic FV-1115VQ1.

What happens to Panasonic FV-1115VQ1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic FV-1115VQ1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does Panasonic FV-1115VQ1 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Panasonic FV-1115VQ1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Panasonic FV-1115VQ1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic FV-1115VQ1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Panasonic FV-1115VQ1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-1115VQ1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-1115VQ1?

Panasonic FV-1115VQ1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-1115VQ1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-1115VQ1's safe coverage footprint from 50 sq ft to 44 sq ft.