In EPA dataset 8dv7-nngq, Panasonic FV-1315RQ2 tests at 150 CFM free discharge (143.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 143 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-1315RQ2 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 143.3 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.6 CFM/W (#152/1,145)
- Static Retention
- 95.5% @ 0.25"
- Motor Draw
- 14.2 W (5.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Panasonic FV-1315RQ2 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV-1315RQ2 (EPA filing PD #2405524) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 143.3 CFM out of 150 CFM (95.5% retention, 7.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Panasonic registers 92 certified models, with SKU FV-1315RQ2 (series: Whisper Choice) (PD #2405524) certified since 2022-06-24. Lighting kit: No. At 10.6 CFM/W (#152 of 1,145, top 13.7% of 1,145 rated models, more efficient than 86.3% of rated models, 5.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.2 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 124.4 kWh/yr (~$19.90/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).
Why avoid unvented attic termination with Panasonic FV-1315RQ2?
Under ASHRAE 62.2 best practice, Panasonic FV-1315RQ2 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Panasonic FV-1315RQ2?
Before cutting ceiling drywall or sizing attic transitions for Panasonic FV-1315RQ2, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-1315RQ2 / Whisper Choice | PD ID 2405524 (Qualified 2022-06-24) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (143.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Panasonic FV-1315RQ2?
Bathroom ventilation sizing below maps Panasonic FV-1315RQ2 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 143 sq ft | 1 CFM/sq ft @ 143.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 127 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 93 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 124.4 kWh/yr (~$19.90/yr) | 14.2 W x 8,760 hrs / 1,000 |
What peer models sit nearest Panasonic FV-1315RQ2 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Panasonic FV-1315RQ2.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Loren Cook Company GCVF 300 | 167 / N/A CFM | 1.9 sones | 9.9 CFM/W | 8 x 6 in. rectangular |
| S&P PCD150 | 150 / 159.6 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| Broan QTXE110150DC | 150 / 147.8 CFM | Unpublished | 11.0 CFM/W | 6 in. diameter |
What percentage of room demand does Panasonic FV-1315RQ2 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Panasonic FV-1315RQ2 tested delivery.
What plumbing or duct constraints rule out Panasonic FV-1315RQ2?
Compare where Panasonic FV-1315RQ2 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 143.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 143 sq ft
- Suited to: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Panasonic FV-1315RQ2?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Panasonic FV-1315RQ2.
How does Panasonic FV-1315RQ2 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic FV-1315RQ2 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is Panasonic FV-1315RQ2 quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Panasonic FV-1315RQ2 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Panasonic FV-1315RQ2 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Panasonic FV-1315RQ2 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-1315RQ2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-1315RQ2?
Panasonic FV-1315RQ2 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-1315RQ2's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-1315RQ2's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Panasonic FV-1315RQ2 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Panasonic FV-1315RQ2 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Panasonic FV-1315RQ2 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic FV-1315RQ2 lacks adequate reserve.