Skip to main content
Grant Estimator

Broan QTXE110150DC Exhaust Fan Specifications

ENERGY STAR PD #2338634 · Bathroom/Utility Room · Qualified 2019-05-17
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan QTXE110150DC tests at 150 CFM free discharge (147.8 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 147 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXE110150DC Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 147.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.0 CFM/W (#131/1,145)
Static Retention
98.5% @ 0.25"
Motor Draw
13.6 W (5.0 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan QTXE110150DC vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan QTXE110150DC (EPA filing PD #2338634) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 147.8 CFM out of 150 CFM (98.5% retention, 10.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Broan QTXE110150DC (series: QT DC) under PD #2338634 (207 models registered, 2019-05-17). Lighting kit: No. At 11.0 CFM/W (#131 of 1,145, top 12.0% of 1,145 rated models, more efficient than 88.0% of rated models, 6.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.6 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 119.1 kWh/yr (~$19.06/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).

Why avoid unvented attic termination with Broan QTXE110150DC?

Under ASHRAE 62.2 best practice, Broan QTXE110150DC needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan QTXE110150DC?

Before cutting ceiling drywall or sizing attic transitions for Broan QTXE110150DC, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series QTXE110150DC / QT DC PD ID 2338634 (Qualified 2019-05-17)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (147.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Broan QTXE110150DC?

Bathroom ventilation sizing below maps Broan QTXE110150DC motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan QTXE110150DC
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 147 sq ft1 CFM/sq ft @ 147.8 CFM
Tall Bath (9-ft Ceiling)Up to 131 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 97 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.0 kWh/yr (~$0.80/yr)13.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2119.1 kWh/yr (~$19.06/yr)13.6 W x 8,760 hrs / 1,000

What peer models sit nearest Broan QTXE110150DC in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan QTXE110150DC.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
KORA SBF160DC-MS 161.6 / N/A CFM 1.3 sones 8.7 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Panasonic FV-1315RQ2 150 / 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter
Panasonic RG-C1315A 150 / 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter
Panasonic RG-C1315LA 150 / 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter

What percentage of room demand does Broan QTXE110150DC cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan QTXE110150DC tested delivery.

Who should not install Broan QTXE110150DC in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan QTXE110150DC for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 147.8 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around ENERGY STAR sones up to 147 sq ft
  • Primary match: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Broan QTXE110150DC?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan QTXE110150DC.

What electrical efficiency and runtime kWh define Broan QTXE110150DC?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan QTXE110150DC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXE110150DC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan QTXE110150DC?

Broan QTXE110150DC features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan QTXE110150DC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXE110150DC's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan QTXE110150DC satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan QTXE110150DC clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Broan QTXE110150DC undersized or poorly matched for a bath renovation?

Skip Broan QTXE110150DC if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Broan QTXE110150DC CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan QTXE110150DC registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

How does Broan QTXE110150DC sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Broan QTXE110150DC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories