Broan PTE1115RKY Exhaust Fan Specifications

ENERGY STAR PD #4572743 · Bathroom/Utility Room · Qualified 2026-02-25
Verified Specification Summary

Tested under HVI protocols, the Broan PTE1115RKY exhaust unit achieves 150 CFM at 0.1 in. w.g. (154.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 14.2 CFM/W efficacy, covering standard baths up to 154 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan PTE1115RKY Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 154.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
14.2 CFM/W (#37/1,145)
Static Retention
102.9% @ 0.25"
Motor Draw
10.6 W (3.9 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan PTE1115RKY vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan PTE1115RKY (EPA filing PD #4572743) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 154.4 CFM out of 150 CFM (102.9% retention, 15.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Broan PTE1115RKY (series: EVOLVE) under PD #4572743 (207 models registered, 2026-02-25). Lighting kit: No. At 14.2 CFM/W (#37 of 1,145, top 3.8% of 1,145 rated models, more efficient than 96.2% of rated models, 9.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Broan-Nutone PTE1115RK (150.0 CFM) and Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF (150.0 CFM).

What attic duct routing preserves Broan PTE1115RKY CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan PTE1115RKY, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan PTE1115RKY measure up on airflow and noise ratings?

Each row below breaks down Broan PTE1115RKY certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series PTE1115RKY / EVOLVE PD ID 4572743 (Qualified 2026-02-25)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (154.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan PTE1115RKY CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan PTE1115RKY
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 154 sq ft1 CFM/sq ft @ 154.4 CFM
Tall Bath (9-ft Ceiling)Up to 137 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 104 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.9 kWh/yr (~$0.62/yr)10.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.292.9 kWh/yr (~$14.86/yr)10.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan PTE1115RKY?

Compare Broan PTE1115RKY side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan-Nutone PTE1115RK 150 / 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF 150 / 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan-Nutone PTEL1115RK 150 / 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Panasonic FV-1115VK3 150 / 158.7 CFM Unpublished 13.7 CFM/W 6 in. diameter
Panasonic FV-1115VK3 with FV-VS15VK1 150 / 158.7 CFM Unpublished 13.7 CFM/W 6 in. diameter

Can you size Broan PTE1115RKY for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan PTE1115RKY verified capacity.

When does Broan PTE1115RKY fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan PTE1115RKY.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 154.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 154 sq ft
  • Target scenario: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Broan PTE1115RKY?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan PTE1115RKY.

Is Broan PTE1115RKY code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan PTE1115RKY clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Broan PTE1115RKY?

Do not force Broan PTE1115RKY into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Broan PTE1115RKY retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan PTE1115RKY produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will Broan PTE1115RKY disturb adjacent bedrooms during night use?

Acoustic measurement places Broan PTE1115RKY at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Broan PTE1115RKY continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan PTE1115RKY draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Broan PTE1115RKY pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan PTE1115RKY's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan PTE1115RKY?

Broan PTE1115RKY features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan PTE1115RKY's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan PTE1115RKY's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories