Rated for 150 CFM open-air (154.4 CFM at 0.25 in. w.g.), Broan-Nutone PTE1115RK omits a published 0.1-inch sone rating and delivers 14.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 154 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PTE1115RK Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 154.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 14.2 CFM/W (#37/1,145)
- Static Retention
- 102.9% @ 0.25"
- Motor Draw
- 10.6 W (3.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan-Nutone PTE1115RK vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan-Nutone PTE1115RK (EPA filing PD #4191421) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 154.4 CFM out of 150 CFM (102.9% retention, 15.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Broan-Nutone maintains 48 active ENERGY STAR blowers; PTE1115RK (series: PREMIUM) (PD #4191421) gained qualification on 2025-05-23. Lighting kit: No. At 14.2 CFM/W (#37 of 1,145, top 3.8% of 1,145 rated models, more efficient than 96.2% of rated models, 9.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Broan PTE1115RKY (150.0 CFM) and Panasonic FV-1115VK3 (150.0 CFM).
How do flex elbows choke Broan-Nutone PTE1115RK at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan-Nutone PTE1115RK moving full rated CFM.
Does Broan-Nutone PTE1115RK meet residential exhaust fan code specs?
Inspect Broan-Nutone PTE1115RK mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PTE1115RK / PREMIUM | PD ID 4191421 (Qualified 2025-05-23) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (154.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan-Nutone PTE1115RK airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan-Nutone PTE1115RK tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 154 sq ft | 1 CFM/sq ft @ 154.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 137 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 104 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.9 kWh/yr (~$14.86/yr) | 10.6 W x 8,760 hrs / 1,000 |
Which competing models share Broan-Nutone PTE1115RK airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan PTE1115RKY | 150 / 154.4 CFM | Unpublished | 14.2 CFM/W | 6 in. diameter |
| Panasonic FV-1115VK3 | 150 / 158.7 CFM | Unpublished | 13.7 CFM/W | 6 in. diameter |
| Panasonic FV-1115VK3 with FV-VS15VK1 | 150 / 158.7 CFM | Unpublished | 13.7 CFM/W | 6 in. diameter |
| Fantech S110-130-150 (484315) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| Fantech S110-130-150L (484316) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
How much airflow margin does Broan-Nutone PTE1115RK give your bath?
Run a quick local room-volume check for Broan-Nutone PTE1115RK by entering square footage and ceiling height to spot under-vented steam risks early.
Where should contractors skip Broan-Nutone PTE1115RK on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan-Nutone PTE1115RK carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 104 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 154 sq ft with 8-ft ceilings (137 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Broan-Nutone PTE1115RK?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan-Nutone PTE1115RK.
How much power does Broan-Nutone PTE1115RK consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan-Nutone PTE1115RK draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan-Nutone PTE1115RK pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PTE1115RK's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone PTE1115RK?
Broan-Nutone PTE1115RK features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone PTE1115RK's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PTE1115RK's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan-Nutone PTE1115RK score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PTE1115RK delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Broan-Nutone PTE1115RK?
Rule out Broan-Nutone PTE1115RK when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Broan-Nutone PTE1115RK capacity?
Because static drag at 0.25 in. w.g. lowers Broan-Nutone PTE1115RK from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Broan-Nutone PTE1115RK compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Broan-Nutone PTE1115RK produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)