Homeowners specifying Broan MTR2363SS gain 150 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it omits a published 0.1-inch sone rating and delivers 4.6 CFM/W efficacy, venting bathrooms up to 150 sq ft cleanly through 7 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan MTR2363SS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 32.6 W (11.9 kWh/yr)
- Duct & Tier
- 7 in. diameter · Standard

What does Broan MTR2363SS vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan MTR2363SS (EPA filing PD #3945284) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3945284 verifies MTR2363SS (series: RANGE HOOD) under Broan (207 listed models, qualified 2025-01-24). Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).
Which exterior damper path suits Broan MTR2363SS best?
Exterior roof or wall damper termination paired with insulated 7 in. diameter metal pipe prevents condensation buildup around Broan MTR2363SS housings.
Where do Broan MTR2363SS acoustic and static metrics stand?
Compare Broan MTR2363SS published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | MTR2363SS / RANGE HOOD | PD ID 3945284 (Qualified 2025-01-24) |
| Duct Connection | 7 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Broan MTR2363SS handle taller ceilings or walk-in tub steam?
Evaluate how Broan MTR2363SS scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Broan MTR2363SS?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
Is Broan MTR2363SS sized right for your shower or tub room?
Check whether Broan MTR2363SS clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Where should contractors skip Broan MTR2363SS on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan MTR2363SS carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 100 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 150 CFM net static output
- Works well for: Collar pairs with 7 in. diameter duct straight outdoors
Which code checks and cost facts matter for Broan MTR2363SS?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan MTR2363SS.
How much power does Broan MTR2363SS consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan MTR2363SS draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan MTR2363SS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan MTR2363SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan MTR2363SS?
Broan MTR2363SS features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan MTR2363SS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan MTR2363SS's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan MTR2363SS score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan MTR2363SS delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Broan MTR2363SS?
Rule out Broan MTR2363SS when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Broan MTR2363SS capacity?
Because static drag at 0.25 in. w.g. lowers Broan MTR2363SS from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 7 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Broan MTR2363SS compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Broan MTR2363SS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)