In EPA dataset 8dv7-nngq, Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF tests at 150 CFM free discharge (154.4 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 14.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 154 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 154.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 14.2 CFM/W (#37/1,145)
- Static Retention
- 102.9% @ 0.25"
- Motor Draw
- 10.6 W (3.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF (EPA filing PD #4191420) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 154.4 CFM out of 150 CFM (102.9% retention, 15.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Broan-Nutone registers 48 certified models, with SKU PTE1115RK = PTE1115H with PTE1115RKF (series: PREMIUM) (PD #4191420) certified since 2025-05-23. Lighting kit: No. At 14.2 CFM/W (#37 of 1,145, top 3.8% of 1,145 rated models, more efficient than 96.2% of rated models, 9.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Broan PTE1115RKY (150.0 CFM) and Panasonic FV-1115VK3 (150.0 CFM).
Why avoid unvented attic termination with Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF?
Under ASHRAE 62.2 best practice, Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF?
Before cutting ceiling drywall or sizing attic transitions for Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PTE1115RK = PTE1115H with PTE1115RKF / PREMIUM | PD ID 4191420 (Qualified 2025-05-23) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (154.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF?
Bathroom ventilation sizing below maps Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 154 sq ft | 1 CFM/sq ft @ 154.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 137 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 104 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.9 kWh/yr (~$14.86/yr) | 10.6 W x 8,760 hrs / 1,000 |
What peer models sit nearest Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan PTE1115RKY | 150 / 154.4 CFM | Unpublished | 14.2 CFM/W | 6 in. diameter |
| Panasonic FV-1115VK3 | 150 / 158.7 CFM | Unpublished | 13.7 CFM/W | 6 in. diameter |
| Panasonic FV-1115VK3 with FV-VS15VK1 | 150 / 158.7 CFM | Unpublished | 13.7 CFM/W | 6 in. diameter |
| Fantech S110-130-150 (484315) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| Fantech S110-130-150L (484316) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
What percentage of room demand does Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF tested delivery.
When does Broan-Nutone PTE1115RK = PTE1115H with PTE fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone PTE1115RK = PTE1115H with PTE.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 154.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 154 sq ft
- Target scenario: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF.
Will Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF disturb adjacent bedrooms during night use?
Acoustic measurement places Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF?
Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF?
Do not force Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)