Skip to main content
Grant Estimator

Broan-Nutone PTEL1115RK Exhaust Fan Specifications

ENERGY STAR PD #4191425 · Bathroom/Utility Room · Qualified 2025-05-23
Verified Specification Summary

Homeowners specifying Broan-Nutone PTEL1115RK gain 150 CFM at 0.1 in. w.g. (154.4 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 14.2 CFM/W efficacy, venting bathrooms up to 154 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PTEL1115RK Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 154.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
14.2 CFM/W (#37/1,145)
Static Retention
102.9% @ 0.25"
Motor Draw
10.6 W (3.9 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone PTEL1115RK vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone PTEL1115RK (EPA filing PD #4191425) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 154.4 CFM out of 150 CFM (102.9% retention, 15.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Broan-Nutone maintains 48 active ENERGY STAR blowers; PTEL1115RK (series: PREMIUM) (PD #4191425) gained qualification on 2025-05-23. Lighting kit: Yes. At 14.2 CFM/W (#37 of 1,145, top 3.8% of 1,145 rated models, more efficient than 96.2% of rated models, 9.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Broan PTE1115RKY (150.0 CFM) and Panasonic FV-1115VK3 (150.0 CFM).

Which exterior damper path suits Broan-Nutone PTEL1115RK best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Broan-Nutone PTEL1115RK housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan-Nutone PTEL1115RK acoustic and static metrics stand?

Compare Broan-Nutone PTEL1115RK published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series PTEL1115RK / PREMIUM PD ID 4191425 (Qualified 2025-05-23)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (154.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Broan-Nutone PTEL1115RK handle taller ceilings or walk-in tub steam?

Evaluate how Broan-Nutone PTEL1115RK scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan-Nutone PTEL1115RK
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 154 sq ft1 CFM/sq ft @ 154.4 CFM
Tall Bath (9-ft Ceiling)Up to 137 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 104 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.9 kWh/yr (~$0.62/yr)10.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.292.9 kWh/yr (~$14.86/yr)10.6 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan-Nutone PTEL1115RK?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan PTE1115RKY 150 / 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Panasonic FV-1115VK3 150 / 158.7 CFM Unpublished 13.7 CFM/W 6 in. diameter
Panasonic FV-1115VK3 with FV-VS15VK1 150 / 158.7 CFM Unpublished 13.7 CFM/W 6 in. diameter
Fantech S110-130-150 (484315) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech S110-130-150L (484316) 150 / 150 CFM Unpublished 12.9 CFM/W 6 in. diameter

Is Broan-Nutone PTEL1115RK sized right for your shower or tub room?

Check whether Broan-Nutone PTEL1115RK clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does Broan-Nutone PTEL1115RK suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone PTEL1115RK for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 104 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 154.4 CFM net static output
  • Best application: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan-Nutone PTEL1115RK?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan-Nutone PTEL1115RK.

Does duct resistance cut Broan-Nutone PTEL1115RK airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone PTEL1115RK achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Broan-Nutone PTEL1115RK occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan-Nutone PTEL1115RK produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan-Nutone PTEL1115RK add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan-Nutone PTEL1115RK averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan-Nutone PTEL1115RK pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PTEL1115RK's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone PTEL1115RK?

Broan-Nutone PTEL1115RK features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone PTEL1115RK's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PTEL1115RK's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan-Nutone PTEL1115RK pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PTEL1115RK easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan-Nutone PTEL1115RK in a bathroom remodel?

Avoid specifying Broan-Nutone PTEL1115RK in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories