Tested under HVI protocols, the Broan QTXE110150DC=QTXEDCH with QTXE110150DCF exhaust unit achieves 150 CFM at 0.1 in. w.g. (147.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.0 CFM/W efficacy, covering standard baths up to 147 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXE110150DC=QTXEDCH with QTXE110150DCF Exhaust before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 147.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 11.0 CFM/W (#131/1,145)
- Static Retention
- 98.5% @ 0.25"
- Motor Draw
- 13.6 W (5.0 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan QTXE110150DC=QTXEDCH with QTXE110150DCF vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan QTXE110150DC=QTXEDCH with QTXE110150DCF (EPA filing PD #2338635) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 147.8 CFM out of 150 CFM (98.5% retention, 10.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Broan registers 207 certified models, with SKU QTXE110150DC=QTXEDCH with QTXE110150DCF (series: QT DC) (PD #2338635) certified since 2019-05-17. Lighting kit: No. At 11.0 CFM/W (#131 of 1,145, top 12.0% of 1,145 rated models, more efficient than 88.0% of rated models, 6.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.6 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 119.1 kWh/yr (~$19.06/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).
What attic duct routing preserves Broan QTXE110150DC=QTXEDCH with QTXE110150DCF CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan QTXE110150DC=QTXEDCH with QTXE110150DCF, preventing premature peeling paint and mold growth.
How does Broan QTXE110150DC=QTXEDCH with QTXE110150DCF measure up on airflow and noise ratings?
Each row below breaks down Broan QTXE110150DC=QTXEDCH with QTXE110150DCF certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | QTXE110150DC=QTXEDCH with QTXE110150DCF / QT DC | PD ID 2338635 (Qualified 2019-05-17) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (147.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan QTXE110150DC=QTXEDCH with QTXE110150DCF CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 147 sq ft | 1 CFM/sq ft @ 147.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 131 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 97 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.0 kWh/yr (~$0.80/yr) | 13.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 119.1 kWh/yr (~$19.06/yr) | 13.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan QTXE110150DC=QTXEDCH with QTXE110150DCF?
Compare Broan QTXE110150DC=QTXEDCH with QTXE110150DCF side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Panasonic FV-1315RQ2 | 150 / 143.3 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| Panasonic RG-C1315A | 150 / 143.3 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| Panasonic RG-C1315LA | 150 / 143.3 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
Can you size Broan QTXE110150DC=QTXEDCH with QTXE110150DCF for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan QTXE110150DC=QTXEDCH with QTXE110150DCF verified capacity.
Does Broan QTXE110150DC=QTXEDCH with QTXE110150 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan QTXE110150DC=QTXEDCH with QTXE110150 for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 147.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around ENERGY STAR sones up to 147 sq ft
- Best application: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Broan QTXE110150DC=QTXEDCH with QTXE110150DCF?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan QTXE110150DC=QTXEDCH with QTXE110150DCF.
Who should NOT install Broan QTXE110150DC=QTXEDCH with QTXE110150DCF in a bathroom remodel?
Avoid specifying Broan QTXE110150DC=QTXEDCH with QTXE110150DCF in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan QTXE110150DC=QTXEDCH with QTXE110150DCF airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan QTXE110150DC=QTXEDCH with QTXE110150DCF achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Broan QTXE110150DC=QTXEDCH with QTXE110150DCF occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan QTXE110150DC=QTXEDCH with QTXE110150DCF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Broan QTXE110150DC=QTXEDCH with QTXE110150DCF add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan QTXE110150DC=QTXEDCH with QTXE110150DCF averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan QTXE110150DC=QTXEDCH with QTXE110150DCF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXE110150DC=QTXEDCH with QTXE110150DCF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan QTXE110150DC=QTXEDCH with QTXE110150DCF?
Broan QTXE110150DC=QTXEDCH with QTXE110150DCF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan QTXE110150DC=QTXEDCH with QTXE110150DCF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXE110150DC=QTXEDCH with QTXE110150DCF's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan QTXE110150DC=QTXEDCH with QTXE110150DCF pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan QTXE110150DC=QTXEDCH with QTXE110150DCF easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)