Panasonic RG-C1315LA Exhaust Fan Specifications

ENERGY STAR PD #2405791 · Bathroom/Utility Room · Qualified 2022-02-18
Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic RG-C1315LA delivers 150 CFM free-air (143.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 143 sq ft (8-ft height) or 127 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-C1315LA Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 143.3 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
10.6 CFM/W (#152/1,145)
Static Retention
95.5% @ 0.25"
Motor Draw
14.2 W (5.2 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic RG-C1315LA vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic RG-C1315LA (EPA filing PD #2405791) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 143.3 CFM out of 150 CFM (95.5% retention, 7.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU RG-C1315LA (series: Whisper Choice) (PD #2405791) certified since 2022-02-18. Lighting kit: Yes. At 10.6 CFM/W (#152 of 1,145, top 13.7% of 1,145 rated models, more efficient than 86.3% of rated models, 5.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.2 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 124.4 kWh/yr (~$19.90/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).

Why does rigid 6 in. diameter ducting protect Panasonic RG-C1315LA airflow?

Connecting Panasonic RG-C1315LA through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Panasonic RG-C1315LA performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic RG-C1315LA lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series RG-C1315LA / Whisper Choice PD ID 2405791 (Qualified 2022-02-18)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (143.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Panasonic RG-C1315LA?

Calculated coverage metrics translate Panasonic RG-C1315LA airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic RG-C1315LA
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 143 sq ft1 CFM/sq ft @ 143.3 CFM
Tall Bath (9-ft Ceiling)Up to 127 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 93 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.2 kWh/yr (~$0.83/yr)14.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2124.4 kWh/yr (~$19.90/yr)14.2 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Panasonic RG-C1315LA?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
KORA SBF160DC-MS 161.6 / N/A CFM 1.3 sones 8.7 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Loren Cook Company GCVF 300 167 / N/A CFM 1.9 sones 9.9 CFM/W 8 x 6 in. rectangular
S&P PCD150 150 / 159.6 CFM Unpublished 10.6 CFM/W 6 in. diameter
Broan QTXE110150DC 150 / 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter

Does Panasonic RG-C1315LA match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic RG-C1315LA percentage capacity without sending data.

Where should contractors skip Panasonic RG-C1315LA on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic RG-C1315LA carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 93 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 143.3 CFM net static output
  • Works well for: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Panasonic RG-C1315LA?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic RG-C1315LA.

Will long attic ducting choke Panasonic RG-C1315LA capacity?

Because static drag at 0.25 in. w.g. lowers Panasonic RG-C1315LA from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Panasonic RG-C1315LA compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Panasonic RG-C1315LA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Panasonic RG-C1315LA consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Panasonic RG-C1315LA draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Panasonic RG-C1315LA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-C1315LA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic RG-C1315LA?

Panasonic RG-C1315LA features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic RG-C1315LA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-C1315LA's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Panasonic RG-C1315LA score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-C1315LA delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Panasonic RG-C1315LA?

Rule out Panasonic RG-C1315LA when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories