Rated for 150 CFM open-air (143.3 CFM at 0.25 in. w.g.), Panasonic RG-C1315A omits a published 0.1-inch sone rating and delivers 10.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 143 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-C1315A Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 143.3 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.6 CFM/W (#152/1,145)
- Static Retention
- 95.5% @ 0.25"
- Motor Draw
- 14.2 W (5.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Panasonic RG-C1315A vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic RG-C1315A (EPA filing PD #2398539) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 143.3 CFM out of 150 CFM (95.5% retention, 7.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Panasonic registers 92 certified models, with SKU RG-C1315A (series: Whisper Choice) (PD #2398539) certified since 2022-03-18. Lighting kit: No. At 10.6 CFM/W (#152 of 1,145, top 13.7% of 1,145 rated models, more efficient than 86.3% of rated models, 5.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.2 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 124.4 kWh/yr (~$19.90/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).
How do flex elbows choke Panasonic RG-C1315A at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Panasonic RG-C1315A moving full rated CFM.
Does Panasonic RG-C1315A meet residential exhaust fan code specs?
Inspect Panasonic RG-C1315A mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RG-C1315A / Whisper Choice | PD ID 2398539 (Qualified 2022-03-18) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (143.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Panasonic RG-C1315A airflow output?
Annual electricity figures and room square-footage ceilings below reflect Panasonic RG-C1315A tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 143 sq ft | 1 CFM/sq ft @ 143.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 127 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 93 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 124.4 kWh/yr (~$19.90/yr) | 14.2 W x 8,760 hrs / 1,000 |
Which competing models share Panasonic RG-C1315A airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Loren Cook Company GCVF 300 | 167 / N/A CFM | 1.9 sones | 9.9 CFM/W | 8 x 6 in. rectangular |
| S&P PCD150 | 150 / 159.6 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| Broan QTXE110150DC | 150 / 147.8 CFM | Unpublished | 11.0 CFM/W | 6 in. diameter |
How much airflow margin does Panasonic RG-C1315A give your bath?
Run a quick local room-volume check for Panasonic RG-C1315A by entering square footage and ceiling height to spot under-vented steam risks early.
Where should contractors skip Panasonic RG-C1315A on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic RG-C1315A carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 93 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 143 sq ft with 8-ft ceilings (127 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Panasonic RG-C1315A?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic RG-C1315A.
Will long attic ducting choke Panasonic RG-C1315A capacity?
Because static drag at 0.25 in. w.g. lowers Panasonic RG-C1315A from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Panasonic RG-C1315A compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Panasonic RG-C1315A produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Panasonic RG-C1315A consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Panasonic RG-C1315A draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Panasonic RG-C1315A pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-C1315A's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic RG-C1315A?
Panasonic RG-C1315A features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic RG-C1315A's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-C1315A's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Panasonic RG-C1315A score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-C1315A delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Panasonic RG-C1315A?
Rule out Panasonic RG-C1315A when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)