Homeowners specifying S&P PCD150 gain 150 CFM at 0.1 in. w.g. (159.6 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 10.6 CFM/W efficacy, venting bathrooms up to 159 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCD150 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 159.6 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.6 CFM/W (#152/1,145)
- Static Retention
- 106.4% @ 0.25"
- Motor Draw
- 14.2 W (5.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does S&P PCD150 vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P PCD150 (EPA filing PD #4497661) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 159.6 CFM out of 150 CFM (106.4% retention, 18.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms S&P PCD150 (series: PCD) under PD #4497661 (29 models registered, 2025-08-22). Lighting kit: No. At 10.6 CFM/W (#152 of 1,145, top 13.7% of 1,145 rated models, more efficient than 86.3% of rated models, 5.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.2 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 124.4 kWh/yr (~$19.90/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).
Which exterior damper path suits S&P PCD150 best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around S&P PCD150 housings.
Where do S&P PCD150 acoustic and static metrics stand?
Compare S&P PCD150 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PCD150 / PCD | PD ID 4497661 (Qualified 2025-08-22) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (159.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can S&P PCD150 handle taller ceilings or walk-in tub steam?
Evaluate how S&P PCD150 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 159 sq ft | 1 CFM/sq ft @ 159.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 141 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 109 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 124.4 kWh/yr (~$19.90/yr) | 14.2 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near S&P PCD150?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Loren Cook Company GCVF 300 | 167 / N/A CFM | 1.9 sones | 9.9 CFM/W | 8 x 6 in. rectangular |
| Panasonic FV-1315RQ2 | 150 / 143.3 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| Panasonic RG-C1315A | 150 / 143.3 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
Is S&P PCD150 sized right for your shower or tub room?
Check whether S&P PCD150 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Where should contractors skip S&P PCD150 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P PCD150 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 109 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 159.6 CFM net static output
- Works well for: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for S&P PCD150?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to S&P PCD150.
How loud is S&P PCD150 compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, S&P PCD150 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does S&P PCD150 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, S&P PCD150 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can S&P PCD150 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCD150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P PCD150?
S&P PCD150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P PCD150's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCD150's safe coverage footprint from 50 sq ft to 44 sq ft.
How does S&P PCD150 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P PCD150 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify S&P PCD150?
Rule out S&P PCD150 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke S&P PCD150 capacity?
Because static drag at 0.25 in. w.g. lowers S&P PCD150 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)