In EPA dataset 8dv7-nngq, Panasonic RG-R811A tests at 110 CFM free discharge (92.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 6.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 92 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-R811A Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 92.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 6.1 CFM/W (#448/1,145)
- Static Retention
- 83.7% @ 0.25"
- Motor Draw
- 18.0 W (6.6 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Panasonic RG-R811A vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic RG-R811A (EPA filing PD #2405531) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.1 CFM at 0.25 in. w.g. (83.7% retention, 4.0 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places RG-R811A (series: Whisper Remodel) (PD #2405531) among 92 Panasonic entries qualified through 2022-12-09. Lighting kit: No. At 6.1 CFM/W (#448 of 1,145, top 40.0% of 1,145 rated models, more efficient than 60.0% of rated models, 1.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.0 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 157.7 kWh/yr (~$25.23/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Tech Drive TD-BF-10 (110.0 CFM).
Why avoid unvented attic termination with Panasonic RG-R811A?
Under ASHRAE 62.2 best practice, Panasonic RG-R811A needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Panasonic RG-R811A?
Before cutting ceiling drywall or sizing attic transitions for Panasonic RG-R811A, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RG-R811A / Whisper Remodel | PD ID 2405531 (Qualified 2022-12-09) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (92.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Panasonic RG-R811A?
Bathroom ventilation sizing below maps Panasonic RG-R811A motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 157.7 kWh/yr (~$25.23/yr) | 18.0 W x 8,760 hrs / 1,000 |
What peer models sit nearest Panasonic RG-R811A in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Panasonic RG-R811A.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Tech Drive TD-BF-10 | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TG-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TGHS | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
What percentage of room demand does Panasonic RG-R811A cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Panasonic RG-R811A tested delivery.
Where should contractors skip Panasonic RG-R811A on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic RG-R811A carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 92.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 92 sq ft
- Works well for: Paired with rigid galvanized 3 in. diameter transition
Where do official rules set limits for Panasonic RG-R811A?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Panasonic RG-R811A.
Will long attic ducting choke Panasonic RG-R811A capacity?
Because static drag at 0.25 in. w.g. lowers Panasonic RG-R811A from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 3 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Panasonic RG-R811A compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Panasonic RG-R811A produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Panasonic RG-R811A consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Panasonic RG-R811A draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Panasonic RG-R811A pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-R811A's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic RG-R811A?
Panasonic RG-R811A features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic RG-R811A's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-R811A's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Panasonic RG-R811A score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-R811A delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Panasonic RG-R811A?
Rule out Panasonic RG-R811A when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)