Skip to main content
Grant Estimator

Panasonic RG-T810LA Exhaust Fan Specifications

ENERGY STAR PD #2405786 · Bathroom/Utility Room · Qualified 2022-12-09
Verified Specification Summary

Homeowners specifying Panasonic RG-T810LA gain 100 CFM at 0.1 in. w.g. (100.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 7.6 CFM/W efficacy, venting bathrooms up to 100 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-T810LA Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 100.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.6 CFM/W (#380/1,145)
Static Retention
100.1% @ 0.25"
Motor Draw
13.2 W (4.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic RG-T810LA vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic RG-T810LA (EPA filing PD #2405786) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.1 CFM out of 100 CFM (100.1% retention, 12.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU RG-T810LA (series: Whisper Thin) (PD #2405786) certified since 2022-12-09. Lighting kit: Yes. At 7.6 CFM/W (#380 of 1,145, top 34.0% of 1,145 rated models, more efficient than 66.0% of rated models, 2.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.2 watts, about 4.8 kWh/yr (~$0.77/yr at $0.16/kWh) for 1 hr/day shower timers or 115.6 kWh/yr (~$18.50/yr) continuously. Closest competing matches include Delta ITG100 (100.0 CFM) and Utilitech 7131-04 (100.0 CFM).

Which exterior damper path suits Panasonic RG-T810LA best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic RG-T810LA housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Panasonic RG-T810LA acoustic and static metrics stand?

Compare Panasonic RG-T810LA published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series RG-T810LA / Whisper Thin PD ID 2405786 (Qualified 2022-12-09)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (100.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Panasonic RG-T810LA handle taller ceilings or walk-in tub steam?

Evaluate how Panasonic RG-T810LA scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Panasonic RG-T810LA
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 100 sq ft1 CFM/sq ft @ 100.1 CFM
Tall Bath (9-ft Ceiling)Up to 88 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 50 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.8 kWh/yr (~$0.77/yr)13.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2115.6 kWh/yr (~$18.50/yr)13.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Panasonic RG-T810LA?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta ITG100 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter
Utilitech 7131-04 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter
Delta 100LED 100 / 75 CFM 1.5 sones 7.4 CFM/W 4 in. diameter
Delta GBR100LED 100 / 75 CFM 1.5 sones 7.4 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Is Panasonic RG-T810LA sized right for your shower or tub room?

Check whether Panasonic RG-T810LA clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out Panasonic RG-T810LA?

Compare where Panasonic RG-T810LA excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 50 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 100.1 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Panasonic RG-T810LA?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic RG-T810LA.

How does Panasonic RG-T810LA handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic RG-T810LA yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Panasonic RG-T810LA quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Panasonic RG-T810LA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Panasonic RG-T810LA energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Panasonic RG-T810LA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-T810LA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic RG-T810LA?

Panasonic RG-T810LA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic RG-T810LA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-T810LA's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Panasonic RG-T810LA serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Panasonic RG-T810LA supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Panasonic RG-T810LA for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic RG-T810LA lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories