Homeowners specifying Panasonic RG-T810LA gain 100 CFM at 0.1 in. w.g. (100.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 7.6 CFM/W efficacy, venting bathrooms up to 100 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-T810LA Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 100.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.6 CFM/W (#380/1,145)
- Static Retention
- 100.1% @ 0.25"
- Motor Draw
- 13.2 W (4.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic RG-T810LA vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic RG-T810LA (EPA filing PD #2405786) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.1 CFM out of 100 CFM (100.1% retention, 12.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Panasonic registers 92 certified models, with SKU RG-T810LA (series: Whisper Thin) (PD #2405786) certified since 2022-12-09. Lighting kit: Yes. At 7.6 CFM/W (#380 of 1,145, top 34.0% of 1,145 rated models, more efficient than 66.0% of rated models, 2.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.2 watts, about 4.8 kWh/yr (~$0.77/yr at $0.16/kWh) for 1 hr/day shower timers or 115.6 kWh/yr (~$18.50/yr) continuously. Closest competing matches include Delta ITG100 (100.0 CFM) and Utilitech 7131-04 (100.0 CFM).
Which exterior damper path suits Panasonic RG-T810LA best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic RG-T810LA housings.
Where do Panasonic RG-T810LA acoustic and static metrics stand?
Compare Panasonic RG-T810LA published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RG-T810LA / Whisper Thin | PD ID 2405786 (Qualified 2022-12-09) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Panasonic RG-T810LA handle taller ceilings or walk-in tub steam?
Evaluate how Panasonic RG-T810LA scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.8 kWh/yr (~$0.77/yr) | 13.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 115.6 kWh/yr (~$18.50/yr) | 13.2 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Panasonic RG-T810LA?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta ITG100 | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
| Utilitech 7131-04 | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
| Delta 100LED | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| Delta GBR100LED | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Is Panasonic RG-T810LA sized right for your shower or tub room?
Check whether Panasonic RG-T810LA clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
What plumbing or duct constraints rule out Panasonic RG-T810LA?
Compare where Panasonic RG-T810LA excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 50 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 100.1 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Panasonic RG-T810LA?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic RG-T810LA.
How does Panasonic RG-T810LA handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic RG-T810LA yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Panasonic RG-T810LA quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Panasonic RG-T810LA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Panasonic RG-T810LA energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Panasonic RG-T810LA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-T810LA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic RG-T810LA?
Panasonic RG-T810LA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic RG-T810LA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-T810LA's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Panasonic RG-T810LA serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Panasonic RG-T810LA supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Panasonic RG-T810LA for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic RG-T810LA lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)