Rated for 110 CFM open-air (111.7 CFM at 0.25 in. w.g.), Panasonic RG-Y811SLA omits a published 0.1-inch sone rating and delivers 10.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 111 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-Y811SLA Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 111.7 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.2 CFM/W (#179/1,145)
- Static Retention
- 101.5% @ 0.25"
- Motor Draw
- 10.8 W (3.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic RG-Y811SLA vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic RG-Y811SLA (EPA filing PD #4514158) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.7 CFM out of 110 CFM (101.5% retention, 13.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Panasonic RG-Y811SLA (series: WhisperSymphony) under PD #4514158 (92 models registered, 2025-09-05). Lighting kit: Yes. At 10.2 CFM/W (#179 of 1,145, top 16.2% of 1,145 rated models, more efficient than 83.8% of rated models, 5.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
How do flex elbows choke Panasonic RG-Y811SLA at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Panasonic RG-Y811SLA moving full rated CFM.
Does Panasonic RG-Y811SLA meet residential exhaust fan code specs?
Inspect Panasonic RG-Y811SLA mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RG-Y811SLA / WhisperSymphony | PD ID 4514158 (Qualified 2025-09-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (111.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Panasonic RG-Y811SLA airflow output?
Annual electricity figures and room square-footage ceilings below reflect Panasonic RG-Y811SLA tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 111 sq ft | 1 CFM/sq ft @ 111.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 61 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 94.6 kWh/yr (~$15.14/yr) | 10.8 W x 8,760 hrs / 1,000 |
Which competing models share Panasonic RG-Y811SLA airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
How much airflow margin does Panasonic RG-Y811SLA give your bath?
Run a quick local room-volume check for Panasonic RG-Y811SLA by entering square footage and ceiling height to spot under-vented steam risks early.
What plumbing or duct constraints rule out Panasonic RG-Y811SLA?
Compare where Panasonic RG-Y811SLA excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 61 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 111 sq ft with 8-ft ceilings (99 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Panasonic RG-Y811SLA?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic RG-Y811SLA.
How does Panasonic RG-Y811SLA handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic RG-Y811SLA yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Panasonic RG-Y811SLA quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Panasonic RG-Y811SLA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Panasonic RG-Y811SLA energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Panasonic RG-Y811SLA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-Y811SLA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic RG-Y811SLA?
Panasonic RG-Y811SLA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic RG-Y811SLA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-Y811SLA's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Panasonic RG-Y811SLA serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Panasonic RG-Y811SLA supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Panasonic RG-Y811SLA for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic RG-Y811SLA lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)