In EPA dataset 8dv7-nngq, S&P PCLP100 tests at 100 CFM free discharge (90.2 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 4.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 90 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLP100 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 90.2 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 90.2% @ 0.25"
- Motor Draw
- 23.8 W (8.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does S&P PCLP100 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 90.2 CFM out of 100 CFM (90.2% retention, 2.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2382308 verifies PCLP100 (series: PCLP) under S&P (29 listed models, qualified 2021-07-16). Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.8 watts, about 8.7 kWh/yr (~$1.39/yr at $0.16/kWh) for 1 hr/day shower timers or 208.5 kWh/yr (~$33.36/yr) continuously. Closest competing matches include Broan L100EL (100.0 CFM) and Panasonic FV-0811RF1 (100.0 CFM).
Does S&P PCLP100 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with S&P PCLP100 at 2.0 sones.
Why avoid unvented attic termination with S&P PCLP100?
Under ASHRAE 62.2 best practice, S&P PCLP100 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern S&P PCLP100?
Before cutting ceiling drywall or sizing attic transitions for S&P PCLP100, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PCLP100 / PCLP | PD ID 2382308 (Qualified 2021-07-16) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (90.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit S&P PCLP100?
Bathroom ventilation sizing below maps S&P PCLP100 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 90 sq ft | 1 CFM/sq ft @ 90.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 40 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.7 kWh/yr (~$1.39/yr) | 23.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 208.5 kWh/yr (~$33.36/yr) | 23.8 W x 8,760 hrs / 1,000 |
What peer models sit nearest S&P PCLP100 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P PCLP100.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan L100EL | 100 / N/A CFM | Unpublished | 4.3 CFM/W | 8 in. diameter |
| Panasonic FV-0811RF1 | 100 / 103.6 CFM | Unpublished | 4.0 CFM/W | 4 in. diameter |
| ACIQ AP100 | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Air King FR100 | 100 / 82.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Anzzi EF-AZ107WH | 100 / 92.2 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
What percentage of room demand does S&P PCLP100 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P PCLP100 tested delivery.
Who should not install S&P PCLP100 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting S&P PCLP100 for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 90.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 2.0 sones up to 90 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for S&P PCLP100?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P PCLP100.
Why check S&P PCLP100 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, S&P PCLP100 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does S&P PCLP100 sound output compare to noisy contractor-grade fans?
Rated at 2.0 sones, S&P PCLP100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define S&P PCLP100?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can S&P PCLP100 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLP100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P PCLP100?
S&P PCLP100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P PCLP100's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLP100's safe coverage footprint from 50 sq ft to 44 sq ft.
Does S&P PCLP100 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), S&P PCLP100 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is S&P PCLP100 undersized or poorly matched for a bath renovation?
Skip S&P PCLP100 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.