S&P PCLP100 Exhaust Fan Specifications

ENERGY STAR PD #2382308 · Bathroom/Utility Room · Qualified 2021-07-16
Verified Specification Summary

In EPA dataset 8dv7-nngq, S&P PCLP100 tests at 100 CFM free discharge (90.2 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 4.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 90 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLP100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 90.2 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
90.2% @ 0.25"
Motor Draw
23.8 W (8.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PCLP100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 90.2 CFM out of 100 CFM (90.2% retention, 2.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2382308 verifies PCLP100 (series: PCLP) under S&P (29 listed models, qualified 2021-07-16). Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.8 watts, about 8.7 kWh/yr (~$1.39/yr at $0.16/kWh) for 1 hr/day shower timers or 208.5 kWh/yr (~$33.36/yr) continuously. Closest competing matches include Broan L100EL (100.0 CFM) and Panasonic FV-0811RF1 (100.0 CFM).

Does S&P PCLP100 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with S&P PCLP100 at 2.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

Why avoid unvented attic termination with S&P PCLP100?

Under ASHRAE 62.2 best practice, S&P PCLP100 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern S&P PCLP100?

Before cutting ceiling drywall or sizing attic transitions for S&P PCLP100, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PCLP100 / PCLP PD ID 2382308 (Qualified 2021-07-16)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (90.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit S&P PCLP100?

Bathroom ventilation sizing below maps S&P PCLP100 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for S&P PCLP100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 90 sq ft1 CFM/sq ft @ 90.2 CFM
Tall Bath (9-ft Ceiling)Up to 80 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 40 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.7 kWh/yr (~$1.39/yr)23.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2208.5 kWh/yr (~$33.36/yr)23.8 W x 8,760 hrs / 1,000

What peer models sit nearest S&P PCLP100 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P PCLP100.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan L100EL 100 / N/A CFM Unpublished 4.3 CFM/W 8 in. diameter
Panasonic FV-0811RF1 100 / 103.6 CFM Unpublished 4.0 CFM/W 4 in. diameter
ACIQ AP100 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Air King FR100 100 / 82.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ107WH 100 / 92.2 CFM 2.0 sones (Same) 3.9 CFM/W 4 in. diameter

What percentage of room demand does S&P PCLP100 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P PCLP100 tested delivery.

Who should not install S&P PCLP100 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting S&P PCLP100 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 90.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 2.0 sones up to 90 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for S&P PCLP100?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P PCLP100.

Why check S&P PCLP100 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, S&P PCLP100 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does S&P PCLP100 sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, S&P PCLP100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define S&P PCLP100?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can S&P PCLP100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLP100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PCLP100?

S&P PCLP100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PCLP100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLP100's safe coverage footprint from 50 sq ft to 44 sq ft.

Does S&P PCLP100 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), S&P PCLP100 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is S&P PCLP100 undersized or poorly matched for a bath renovation?

Skip S&P PCLP100 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.