Tech Drive TD-BF-03-1 Exhaust Fan Specifications

ENERGY STAR PD #4429495 · Bathroom/Utility Room · Qualified 2025-06-06
Verified Specification Summary

Rated for 70 CFM open-air (58.9 CFM at 0.25 in. w.g.), Tech Drive TD-BF-03-1 registers #522 of 607 in quietness (2.0 sones) and delivers 3.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 58 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-03-1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 58.9 CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
84.1% @ 0.25"
Motor Draw
18.4 W (6.7 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Tech Drive TD-BF-03-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 58.9 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Tech Drive's 27-unit lineup, TD-BF-03-1 (series: TD) carries PD #4429495 dating to 2025-06-06. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.4 watts, about 6.7 kWh/yr (~$1.07/yr at $0.16/kWh) for 1 hr/day shower timers or 161.2 kWh/yr (~$25.79/yr) continuously. Closest competing matches include Broan BEL7A (70.0 CFM) and HomeWerks Worldwide 299650A (70.0 CFM).

How does Tech Drive TD-BF-03-1 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Tech Drive TD-BF-03-1 (2.0 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

How do flex elbows choke Tech Drive TD-BF-03-1 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Tech Drive TD-BF-03-1 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Tech Drive TD-BF-03-1 meet residential exhaust fan code specs?

Inspect Tech Drive TD-BF-03-1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Tech Drive (27 models) ENERGY STAR Certified Partner
Model Number & Series TD-BF-03-1 / TD PD ID 4429495 (Qualified 2025-06-06)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (58.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Tech Drive TD-BF-03-1 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Tech Drive TD-BF-03-1 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-03-1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 58 sq ft1 CFM/sq ft @ 58.9 CFM
Tall Bath (9-ft Ceiling)Up to 52 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.7 kWh/yr (~$1.07/yr)18.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2161.2 kWh/yr (~$25.79/yr)18.4 W x 8,760 hrs / 1,000

Which competing models share Tech Drive TD-BF-03-1 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan BEL7A 70 / 57.4 CFM 2.0 sones (Same) 3.8 CFM/W 4 in. diameter
HomeWerks Worldwide 299650A 70 / 58.9 CFM 2.0 sones (Same) 3.8 CFM/W 3 in. diameter
VENTECHLATION BPT13-13EN-T 70 / 58.9 CFM 2.0 sones (Same) 3.8 CFM/W 3 in. diameter
VENTECHLATION BPT13-13EN3 70 / 58.9 CFM 2.0 sones (Same) 3.8 CFM/W 3 in. diameter
Air King BFQ75 70 / 60.6 CFM 2.0 sones (Same) 3.4 CFM/W 4 in. diameter

How much airflow margin does Tech Drive TD-BF-03-1 give your bath?

Run a quick local room-volume check for Tech Drive TD-BF-03-1 by entering square footage and ceiling height to spot under-vented steam risks early.

Who should not install Tech Drive TD-BF-03-1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tech Drive TD-BF-03-1 for residential use.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 58 sq ft with 8-ft ceilings (52 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 3 in. diameter

What should homeowners verify first about Tech Drive TD-BF-03-1?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Tech Drive TD-BF-03-1.

How does Tech Drive TD-BF-03-1 sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, Tech Drive TD-BF-03-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Tech Drive TD-BF-03-1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Tech Drive TD-BF-03-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-03-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Tech Drive TD-BF-03-1?

Tech Drive TD-BF-03-1 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Tech Drive TD-BF-03-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-03-1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Tech Drive TD-BF-03-1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-03-1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Tech Drive TD-BF-03-1 undersized or poorly matched for a bath renovation?

Skip Tech Drive TD-BF-03-1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Tech Drive TD-BF-03-1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tech Drive TD-BF-03-1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories