In EPA dataset 8dv7-nngq, VENTECHLATION BPT13-13EN-T tests at 70 CFM free discharge (58.9 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 58 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION BPT13-13EN-T Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 58.9 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 84.1% @ 0.25"
- Motor Draw
- 18.4 W (6.7 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does VENTECHLATION BPT13-13EN-T vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 70 CFM open-air to 58.9 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places BPT13-13EN-T (series: BPT) (PD #4429502) among 12 VENTECHLATION entries qualified through 2025-06-06. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.4 watts, about 6.7 kWh/yr (~$1.07/yr at $0.16/kWh) for 1 hr/day shower timers or 161.2 kWh/yr (~$25.79/yr) continuously. Closest competing matches include Broan BEL7A (70.0 CFM) and HomeWerks Worldwide 299650A (70.0 CFM).
Does VENTECHLATION BPT13-13EN-T fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with VENTECHLATION BPT13-13EN-T at 2.0 sones.
Why avoid unvented attic termination with VENTECHLATION BPT13-13EN-T?
Under ASHRAE 62.2 best practice, VENTECHLATION BPT13-13EN-T needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern VENTECHLATION BPT13-13EN-T?
Before cutting ceiling drywall or sizing attic transitions for VENTECHLATION BPT13-13EN-T, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT13-13EN-T / BPT | PD ID 4429502 (Qualified 2025-06-06) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (58.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit VENTECHLATION BPT13-13EN-T?
Bathroom ventilation sizing below maps VENTECHLATION BPT13-13EN-T motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 58 sq ft | 1 CFM/sq ft @ 58.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.7 kWh/yr (~$1.07/yr) | 18.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 161.2 kWh/yr (~$25.79/yr) | 18.4 W x 8,760 hrs / 1,000 |
What peer models sit nearest VENTECHLATION BPT13-13EN-T in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to VENTECHLATION BPT13-13EN-T.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan BEL7A | 70 / 57.4 CFM | 2.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 299650A | 70 / 58.9 CFM | 2.0 sones (Same) | 3.8 CFM/W | 3 in. diameter |
| Tech Drive TD-BF-03-1 | 70 / 58.9 CFM | 2.0 sones (Same) | 3.8 CFM/W | 3 in. diameter |
| Air King BFQ75 | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| Air King WM70 | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
What percentage of room demand does VENTECHLATION BPT13-13EN-T cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against VENTECHLATION BPT13-13EN-T tested delivery.
Does VENTECHLATION BPT13-13EN-T suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying VENTECHLATION BPT13-13EN-T for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 58.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 2.0 sones up to 58 sq ft
- Best application: Paired with rigid galvanized 3 in. diameter transition
Where do official rules set limits for VENTECHLATION BPT13-13EN-T?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing VENTECHLATION BPT13-13EN-T.
How many kWh per year does VENTECHLATION BPT13-13EN-T add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, VENTECHLATION BPT13-13EN-T averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can VENTECHLATION BPT13-13EN-T pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION BPT13-13EN-T's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VENTECHLATION BPT13-13EN-T?
VENTECHLATION BPT13-13EN-T features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VENTECHLATION BPT13-13EN-T's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION BPT13-13EN-T's safe coverage footprint from 50 sq ft to 44 sq ft.
Does VENTECHLATION BPT13-13EN-T pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION BPT13-13EN-T easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install VENTECHLATION BPT13-13EN-T in a bathroom remodel?
Avoid specifying VENTECHLATION BPT13-13EN-T in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut VENTECHLATION BPT13-13EN-T airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, VENTECHLATION BPT13-13EN-T achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does VENTECHLATION BPT13-13EN-T occupy in EPA filings?
With 2.0 sones at 0.1 in. w.g., VENTECHLATION BPT13-13EN-T produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)