Homeowners specifying VENTECHLATION BPT13-13EN3 gain 70 CFM at 0.1 in. w.g. (58.9 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 3.8 CFM/W efficacy, venting bathrooms up to 58 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION BPT13-13EN3 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 58.9 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 84.1% @ 0.25"
- Motor Draw
- 18.4 W (6.7 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does VENTECHLATION BPT13-13EN3 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 70 CFM open-air to 58.9 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: VENTECHLATION registers 12 certified models, with SKU BPT13-13EN3 (series: BPT) (PD #4429499) certified since 2025-06-06. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.4 watts, about 6.7 kWh/yr (~$1.07/yr at $0.16/kWh) for 1 hr/day shower timers or 161.2 kWh/yr (~$25.79/yr) continuously. Closest competing matches include Broan BEL7A (70.0 CFM) and HomeWerks Worldwide 299650A (70.0 CFM).
What acoustic percentile does VENTECHLATION BPT13-13EN3 occupy among 1,145 bath blowers?
Inspect how VENTECHLATION BPT13-13EN3 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits VENTECHLATION BPT13-13EN3 best?
Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around VENTECHLATION BPT13-13EN3 housings.
Where do VENTECHLATION BPT13-13EN3 acoustic and static metrics stand?
Compare VENTECHLATION BPT13-13EN3 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT13-13EN3 / BPT | PD ID 4429499 (Qualified 2025-06-06) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (58.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can VENTECHLATION BPT13-13EN3 handle taller ceilings or walk-in tub steam?
Evaluate how VENTECHLATION BPT13-13EN3 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 58 sq ft | 1 CFM/sq ft @ 58.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.7 kWh/yr (~$1.07/yr) | 18.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 161.2 kWh/yr (~$25.79/yr) | 18.4 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near VENTECHLATION BPT13-13EN3?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan BEL7A | 70 / 57.4 CFM | 2.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 299650A | 70 / 58.9 CFM | 2.0 sones (Same) | 3.8 CFM/W | 3 in. diameter |
| Tech Drive TD-BF-03-1 | 70 / 58.9 CFM | 2.0 sones (Same) | 3.8 CFM/W | 3 in. diameter |
| Air King BFQ75 | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| Air King WM70 | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
Is VENTECHLATION BPT13-13EN3 sized right for your shower or tub room?
Check whether VENTECHLATION BPT13-13EN3 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
When does VENTECHLATION BPT13-13EN3 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering VENTECHLATION BPT13-13EN3.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 58.9 CFM net static output
- Target scenario: Collar pairs with 3 in. diameter duct straight outdoors
Which code checks and cost facts matter for VENTECHLATION BPT13-13EN3?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to VENTECHLATION BPT13-13EN3.
Will VENTECHLATION BPT13-13EN3 disturb adjacent bedrooms during night use?
Acoustic measurement places VENTECHLATION BPT13-13EN3 at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running VENTECHLATION BPT13-13EN3 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of VENTECHLATION BPT13-13EN3 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can VENTECHLATION BPT13-13EN3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION BPT13-13EN3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VENTECHLATION BPT13-13EN3?
VENTECHLATION BPT13-13EN3 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VENTECHLATION BPT13-13EN3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION BPT13-13EN3's safe coverage footprint from 50 sq ft to 44 sq ft.
Is VENTECHLATION BPT13-13EN3 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION BPT13-13EN3 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than VENTECHLATION BPT13-13EN3?
Do not force VENTECHLATION BPT13-13EN3 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does VENTECHLATION BPT13-13EN3 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, VENTECHLATION BPT13-13EN3 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.