Skip to main content
Grant Estimator

Conservation Management Solutions 50711xx WaterSense Faucet Specifications

EPA WaterSense Certified Faucet · Conservation Management Solutions (1 SKU)
Verified Specification Summary

Homeowners upgrading older 2.75 gpm plumbing to Conservation Management Solutions 50711xx (1.0 gpm, #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets) cut 63.6% off legacy draw, conserving ~7,665 gallons yearly for a 3-person household. Compare EPA WaterSense certified flow metrics for Conservation Management Solutions 50711xx WaterSense, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.0 gpm
vs. EPAct 1992
-54.5% (2.2 gpm)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
2,555 gal/person
Brand EPA Count
17 faucets
Series / Variants
50711xx (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Conservation Management Solutions 50711xx Benchmark & Water Budget show?

Laboratory testing places Conservation Management Solutions 50711xx at 1.0 gpm (aggressive sub-1.6 gpm conservation tier), saving 54.5% vs. EPAct 1992 (2.2 gpm) while ranking #3 of 22,471 certified faucets; most water-efficient 7.6% of 22,471 certified faucets, lower-flow than 92.4% of certified faucets (0.20 gpm lower-flow than the 1.20 gpm median).

Pair this 1.0 gpm lavatory faucet with single-lever or touchless handles requiring <=5 lbs operating force for arthritic hands, and confirm 1/2-inch supply stops operate cleanly without galvanized sediment.

Brand breadth: Conservation Management Solutions holds 17 certified faucets in EPA files (median 1.2 gpm, range 0.8-1.5). For 3 residents, replacing a 2.75 gpm legacy unit saves ~7,665 gallons/yr—roughly $61/yr in low-tariff towns ($8/1k gal), $84/yr at national averages ($11/1k gal), or $138/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Fairfield (CA) list active rebates among 200 U.S. programs. Closest alternatives: allen + roth QFS6A0229 (1.0 gpm) and Belanger IND79C (1.0 gpm).

How do federal gpm limits contrast with Conservation Management Solutions 50711xx tested flow?

Each bar isolates Conservation Management Solutions 50711xx (1.00 gpm) relative to the EPA cap, federal EPAct 1992 standard (2.2 gpm), and pre-1994 draw.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpm) (4 items): 50711xx: 1.00; EPA Max Cap: 1.50; EPAct 1992: 2.20; Pre-1994 Legacy: 4.00.Flow Rating Comparison vs Federal & Legacy Thresholds (gpm)50711xx: 1.0050711xx1.00EPA Max Cap: 1.50EPA Max Cap1.50EPAct 1992: 2.20EPAct 19922.20Pre-1994 Legacy: 4.00Pre-1994 Legacy4.00
Registry Flow Distribution (Faucet)Histogram of 22471 items for Registry Flow Distribution (Faucet). Min 0.8 gpm, median 1.2 gpm, max 1.5 gpm. Marker 1.0 gpm: 1 gpm (8th percentile).Registry Flow Distribution (Faucet)n=22471 · median 1.2 gpm06688133760.8 gpm to 0.87 gpm: 20.87 gpm to 0.94 gpm: 00.94 gpm to 1.01 gpm: 17011.01 gpm to 1.08 gpm: 01.08 gpm to 1.15 gpm: 71.15 gpm to 1.22 gpm: 133761.22 gpm to 1.29 gpm: 11.29 gpm to 1.36 gpm: 121.36 gpm to 1.43 gpm: 51.43 gpm to 1.5 gpm: 73670.8 gpm1.15 gpm1.5 gpm1.0 gpm: 1 gpm (P8)

How does wet-zone tile prep interact with Conservation Management Solutions 50711xx rough-ins?

Installers verify acrylic-primed underlayment flatness and flush closet flange height alongside ASSE 1016 valve rough-ins during bath trim-out.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What plumbing standards accompany Conservation Management Solutions 50711xx installation?

Verify Conservation Management Solutions 50711xx EPA WaterSense flow compliance, rough-in compatibility, and anti-scald or drain-carry checkpoints prior to purchasing hardware.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Conservation Management Solutions (17 certified) EPA WaterSense Partner
Model Number / Series 50711xx Certified Series (1 finish variants)
Rated Consumption 1.0 gpm Category median 1.2 gpm (n=22,471 rated)
Shower / Faucet Pairing Pair w/ ASSE 1016 valve (IPC 412.3) Verify rough-in & supply pressure

What household water budget fits Conservation Management Solutions 50711xx?

Annual consumption rows below translate Conservation Management Solutions 50711xx certified flow into total gallons used and estimated utility savings compared to un-regulated legacy models.

Computed annual water savings for Conservation Management Solutions 50711xx (1.0 gpm)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,752 gal2,555 gal (~$28)
2 Occupants2,920 gal3,504 gal5,110 gal (~$56)
3 Occupants4,380 gal5,256 gal7,665 gal (~$61–$138)
4 Occupants5,840 gal7,008 gal10,220 gal (~$112)

Where can buyers find alternatives to Conservation Management Solutions 50711xx?

Explore five nearest EPA WaterSense peers matched by certified flow rate and category specs to compare hardware availability and pricing.

Peer faucet models with matching or lower gpm ratings
Peer Brand & ModelRated GPM (Delta)Flush / Model Detail
allen + roth QFS6A0229 1.0 gpm (Same flow) VEDA
Belanger IND79C 1.0 gpm (Same flow) WaterSense
Chicago Faucet E80-A11E-16ABCP 1.0 gpm (Same flow) WaterSense
Conservation Management Systems 50664xx 1.0 gpm (Same flow) WaterSense
Delta 24T2a7b 1.0 gpm (Same flow) WaterSense

What annual bill drop does Conservation Management Solutions 50711xx achieve for your family?

Calculate annual gallons conserved and dollar savings for Conservation Management Solutions 50711xx using your exact occupant count and utility tariff without submitting personal info.

What plumbing or duct constraints rule out Conservation Management Solutions 50711xx?

Compare where Conservation Management Solutions 50711xx excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Existing shower valve lacks ASSE 1016 pressure balancing

Best-Fit Homeowner Profiles

  • Homeowner profile: Meeting 2.2 gpm federal & stricter WaterSense caps
  • Suited to: Targeting ~$84/yr utility savings (3-person home)

Which code checks and cost facts matter for Conservation Management Solutions 50711xx?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Conservation Management Solutions 50711xx.

How do 133 WaterSense rebate programs treat Conservation Management Solutions 50711xx?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Conservation Management Solutions 50711xx, itemized purchase invoices, and residential installation addresses.

How does Conservation Management Solutions 50711xx perform relative to the EPA WaterSense category median?

Among certified WaterSense faucets, the national median stands at 1.2 gpm. At 1.0 gpm, Conservation Management Solutions 50711xx sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Conservation Management Solutions 50711xx?

At $11 per 1,000 gallons, a 3-person household conserving 26,280 gallons/yr with Conservation Management Solutions 50711xx trims roughly $289 annually off water and sewer utility bills.

What anti-scald valve standard pairs with Conservation Management Solutions 50711xx?

Pairing Conservation Management Solutions 50711xx (1.0 gpm) with an IPC 412.3 / ASSE 1016 pressure-balanced or thermostatic mixing valve prevents sudden thermal spikes when other fixtures draw cold water.

How is EPA WaterSense performance tested beyond raw gpm flow caps?

EPA WaterSense certification pairs the 1.0 gpm cap with independent lab testing for spray coverage, thermal stability, and 20-80 PSI retention.

Does installing Conservation Management Solutions 50711xx require a municipal plumbing permit?

Like-for-like swaps using Conservation Management Solutions 50711xx on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Why upgrade a 4.0 gpm fixture to Conservation Management Solutions 50711xx at 1.0 gpm?

Swapping a 4.0 gpm unit for Conservation Management Solutions 50711xx slashes water draw 75.0% (8,760 gal/person/yr), beating 2.2 gpm federal EPAct standards by 54.5%.

When can Conservation Management Solutions 50711xx (1.0 gpm) underperform in an older bathroom?

Skip Conservation Management Solutions 50711xx without addressing static pressure <30 PSI, clogged galvanized risers, or old two-handle mixers lacking ASSE 1016 pressure-balancing cartridges.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories