In EPA dataset 8dv7-nngq, ACIQ AEPD140-3 tests at 140 CFM free discharge (146.6 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 146 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AEPD140-3 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 140 / 146.6 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 11.5 CFM/W (#106/1,145)
- Static Retention
- 104.7% @ 0.25"
- Motor Draw
- 12.2 W (4.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does ACIQ AEPD140-3 vs. 1,145-Model ENERGY STAR Benchmarks show?
ACIQ AEPD140-3 (EPA filing PD #3984073) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 146.6 CFM out of 140 CFM (104.7% retention, 17.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #3984073 verifies AEPD140-3 (series: AEPD) under ACIQ (15 listed models, qualified 2025-01-24). Lighting kit: No. At 11.5 CFM/W (#106 of 1,145, top 10.0% of 1,145 rated models, more efficient than 90.0% of rated models, 6.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and CFM TF140-EC (140.0 CFM).
Why avoid unvented attic termination with ACIQ AEPD140-3?
Under ASHRAE 62.2 best practice, ACIQ AEPD140-3 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern ACIQ AEPD140-3?
Before cutting ceiling drywall or sizing attic transitions for ACIQ AEPD140-3, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | ACIQ (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AEPD140-3 / AEPD | PD ID 3984073 (Qualified 2025-01-24) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (146.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit ACIQ AEPD140-3?
Bathroom ventilation sizing below maps ACIQ AEPD140-3 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 146 sq ft | 1 CFM/sq ft @ 146.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 130 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 96 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.9 kWh/yr (~$17.10/yr) | 12.2 W x 8,760 hrs / 1,000 |
What peer models sit nearest ACIQ AEPD140-3 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to ACIQ AEPD140-3.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| CFM TF140-EC | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| Haier QVE110DTWW | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| Ortech ODD-110-18PB | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| S&P PCD110XP | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
What percentage of room demand does ACIQ AEPD140-3 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against ACIQ AEPD140-3 tested delivery.
Who should not install ACIQ AEPD140-3 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting ACIQ AEPD140-3 for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 146.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around ENERGY STAR sones up to 146 sq ft
- Primary match: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for ACIQ AEPD140-3?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing ACIQ AEPD140-3.
Does ACIQ AEPD140-3 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), ACIQ AEPD140-3 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is ACIQ AEPD140-3 undersized or poorly matched for a bath renovation?
Skip ACIQ AEPD140-3 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check ACIQ AEPD140-3 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, ACIQ AEPD140-3 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does ACIQ AEPD140-3 sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, ACIQ AEPD140-3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define ACIQ AEPD140-3?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can ACIQ AEPD140-3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AEPD140-3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing ACIQ AEPD140-3?
ACIQ AEPD140-3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change ACIQ AEPD140-3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AEPD140-3's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)