ACIQ AEPD140-3 Exhaust Fan Specifications

ENERGY STAR PD #3984073 · Bathroom/Utility Room · Qualified 2025-01-24
Verified Specification Summary

In EPA dataset 8dv7-nngq, ACIQ AEPD140-3 tests at 140 CFM free discharge (146.6 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 146 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AEPD140-3 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
140 / 146.6 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.5 CFM/W (#106/1,145)
Static Retention
104.7% @ 0.25"
Motor Draw
12.2 W (4.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does ACIQ AEPD140-3 vs. 1,145-Model ENERGY STAR Benchmarks show?

ACIQ AEPD140-3 (EPA filing PD #3984073) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 146.6 CFM out of 140 CFM (104.7% retention, 17.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #3984073 verifies AEPD140-3 (series: AEPD) under ACIQ (15 listed models, qualified 2025-01-24). Lighting kit: No. At 11.5 CFM/W (#106 of 1,145, top 10.0% of 1,145 rated models, more efficient than 90.0% of rated models, 6.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and CFM TF140-EC (140.0 CFM).

Why avoid unvented attic termination with ACIQ AEPD140-3?

Under ASHRAE 62.2 best practice, ACIQ AEPD140-3 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern ACIQ AEPD140-3?

Before cutting ceiling drywall or sizing attic transitions for ACIQ AEPD140-3, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share ACIQ (15 models) ENERGY STAR Certified Partner
Model Number & Series AEPD140-3 / AEPD PD ID 3984073 (Qualified 2025-01-24)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (146.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit ACIQ AEPD140-3?

Bathroom ventilation sizing below maps ACIQ AEPD140-3 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for ACIQ AEPD140-3
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 146 sq ft1 CFM/sq ft @ 146.6 CFM
Tall Bath (9-ft Ceiling)Up to 130 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 96 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.5 kWh/yr (~$0.72/yr)12.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2106.9 kWh/yr (~$17.10/yr)12.2 W x 8,760 hrs / 1,000

What peer models sit nearest ACIQ AEPD140-3 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to ACIQ AEPD140-3.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
CFM TF140-EC 140 / 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Haier QVE110DTWW 140 / 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Ortech ODD-110-18PB 140 / 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
S&P PCD110XP 140 / 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter

What percentage of room demand does ACIQ AEPD140-3 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against ACIQ AEPD140-3 tested delivery.

Who should not install ACIQ AEPD140-3 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting ACIQ AEPD140-3 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 146.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around ENERGY STAR sones up to 146 sq ft
  • Primary match: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for ACIQ AEPD140-3?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing ACIQ AEPD140-3.

Does ACIQ AEPD140-3 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), ACIQ AEPD140-3 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is ACIQ AEPD140-3 undersized or poorly matched for a bath renovation?

Skip ACIQ AEPD140-3 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check ACIQ AEPD140-3 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, ACIQ AEPD140-3 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

How does ACIQ AEPD140-3 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, ACIQ AEPD140-3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define ACIQ AEPD140-3?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can ACIQ AEPD140-3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AEPD140-3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing ACIQ AEPD140-3?

ACIQ AEPD140-3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change ACIQ AEPD140-3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AEPD140-3's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories