Certified by EPA ENERGY STAR, Broan L100E delivers 140 CFM free-air (100.4 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 100 sq ft (8-ft height) or 89 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan L100E Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 140 / 100.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.5 CFM/W (#471/1,145)
- Static Retention
- 71.7% @ 0.25"
- Motor Draw
- 25.5 W (9.3 kWh/yr)
- Duct & Tier
- 8 in. diameter · Standard

What does Broan L100E vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan L100E (EPA filing PD #2405557) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 140 CFM open-air to 100.4 CFM at 0.25 in. w.g. (71.7% retention, 16.0 pts lower retention than the 87.7% median), making smooth 8 in. diameter rigid metal runs critical. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan L100E (series: LIGHT COMMERCIAL) under PD #2405557 (207 models registered, 2022-12-09). Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 25.5 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 223.4 kWh/yr (~$35.74/yr) continuously. Closest competing matches include Loren Cook Company GC-242 (142.0 CFM) and Nutone QTN130LE1 (130.0 CFM).
Why does rigid 8 in. diameter ducting protect Broan L100E airflow?
Connecting Broan L100E through rigid 8 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan L100E performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan L100E lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | L100E / LIGHT COMMERCIAL | PD ID 2405557 (Qualified 2022-12-09) |
| Duct Connection | 8 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan L100E?
Calculated coverage metrics translate Broan L100E airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 223.4 kWh/yr (~$35.74/yr) | 25.5 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan L100E?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-23L-5CCT(BL) | 130 / 116.4 CFM | 1.2 sones | 4.6 CFM/W | 5 in. diameter |
Does Broan L100E match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan L100E percentage capacity without sending data.
Who should not install Broan L100E in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan L100E for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 50 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 100.4 CFM net static output
- Primary match: Collar pairs with 8 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan L100E?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan L100E.
What electrical efficiency and runtime kWh define Broan L100E?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Broan L100E pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan L100E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan L100E?
Broan L100E features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan L100E's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan L100E's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan L100E satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan L100E clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Broan L100E undersized or poorly matched for a bath renovation?
Skip Broan L100E if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Broan L100E CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan L100E registers unlisted 0.25 in. w.g. backpressure figures, making rigid 8 in. diameter duct runs vital.
How does Broan L100E sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Broan L100E produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)