Tested under HVI protocols, the CFM TF140-EC exhaust unit achieves 140 CFM at 0.1 in. w.g. (146.6 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.5 CFM/W efficacy, covering standard baths up to 146 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside CFM TF140-EC Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 140 / 146.6 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 11.5 CFM/W (#106/1,145)
- Static Retention
- 104.7% @ 0.25"
- Motor Draw
- 12.2 W (4.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does CFM TF140-EC vs. 1,145-Model ENERGY STAR Benchmarks show?
CFM TF140-EC (EPA filing PD #2624891) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 146.6 CFM out of 140 CFM (104.7% retention, 17.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
CFM maintains 4 active ENERGY STAR blowers; TF140-EC (series: TF) (PD #2624891) gained qualification on 2023-07-28. Lighting kit: No. At 11.5 CFM/W (#106 of 1,145, top 10.0% of 1,145 rated models, more efficient than 90.0% of rated models, 6.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and ACIQ AEPD140-3 (140.0 CFM).
What attic duct routing preserves CFM TF140-EC CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on CFM TF140-EC, preventing premature peeling paint and mold growth.
How does CFM TF140-EC measure up on airflow and noise ratings?
Each row below breaks down CFM TF140-EC certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | CFM (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TF140-EC / TF | PD ID 2624891 (Qualified 2023-07-28) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (146.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect CFM TF140-EC CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 146 sq ft | 1 CFM/sq ft @ 146.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 130 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 96 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.9 kWh/yr (~$17.10/yr) | 12.2 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against CFM TF140-EC?
Compare CFM TF140-EC side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| ACIQ AEPD140-3 | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| Haier QVE110DTWW | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| Ortech ODD-110-18PB | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| S&P PCD110XP | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
Can you size CFM TF140-EC for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against CFM TF140-EC verified capacity.
Where should contractors skip CFM TF140-EC on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for CFM TF140-EC carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 146.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 146 sq ft
- Works well for: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to CFM TF140-EC?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for CFM TF140-EC.
How loud is CFM TF140-EC compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, CFM TF140-EC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does CFM TF140-EC consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, CFM TF140-EC draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can CFM TF140-EC pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from CFM TF140-EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing CFM TF140-EC?
CFM TF140-EC features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change CFM TF140-EC's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing CFM TF140-EC's safe coverage footprint from 50 sq ft to 44 sq ft.
How does CFM TF140-EC score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), CFM TF140-EC delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify CFM TF140-EC?
Rule out CFM TF140-EC when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke CFM TF140-EC capacity?
Because static drag at 0.25 in. w.g. lowers CFM TF140-EC from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)