S&P PCD110XP Exhaust Fan Specifications

ENERGY STAR PD #2397153 · Bathroom/Utility Room · Qualified 2022-05-20
Verified Specification Summary

The S&P PCD110XP (PCD) moves 140 CFM at 0.1 in. w.g. (146.6 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 11.5 CFM/W efficacy, sizing bathrooms up to 146 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCD110XP Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
140 / 146.6 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.5 CFM/W (#106/1,145)
Static Retention
104.7% @ 0.25"
Motor Draw
12.2 W (4.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PCD110XP vs. 1,145-Model ENERGY STAR Benchmarks show?

S&P PCD110XP (EPA filing PD #2397153) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 146.6 CFM out of 140 CFM (104.7% retention, 17.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: S&P registers 29 certified models, with SKU PCD110XP (series: PCD) (PD #2397153) certified since 2022-05-20. Lighting kit: No. At 11.5 CFM/W (#106 of 1,145, top 10.0% of 1,145 rated models, more efficient than 90.0% of rated models, 6.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and ACIQ AEPD140-3 (140.0 CFM).

How does duct geometry alter S&P PCD110XP static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to S&P PCD110XP?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for S&P PCD110XP alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PCD110XP / PCD PD ID 2397153 (Qualified 2022-05-20)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (146.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can S&P PCD110XP ventilate safely?

Sizing outputs below convert S&P PCD110XP tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for S&P PCD110XP
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 146 sq ft1 CFM/sq ft @ 146.6 CFM
Tall Bath (9-ft Ceiling)Up to 130 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 96 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.5 kWh/yr (~$0.72/yr)12.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2106.9 kWh/yr (~$17.10/yr)12.2 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match S&P PCD110XP closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
ACIQ AEPD140-3 140 / 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
CFM TF140-EC 140 / 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Haier QVE110DTWW 140 / 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Ortech ODD-110-18PB 140 / 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter

Will S&P PCD110XP clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether S&P PCD110XP satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does S&P PCD110XP fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering S&P PCD110XP.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 96 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 146 sq ft with 8-ft ceilings (130 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern S&P PCD110XP?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting S&P PCD110XP.

Does running S&P PCD110XP continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of S&P PCD110XP draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can S&P PCD110XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCD110XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PCD110XP?

S&P PCD110XP features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PCD110XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCD110XP's safe coverage footprint from 50 sq ft to 44 sq ft.

Is S&P PCD110XP code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), S&P PCD110XP clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than S&P PCD110XP?

Do not force S&P PCD110XP into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does S&P PCD110XP retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, S&P PCD110XP produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will S&P PCD110XP disturb adjacent bedrooms during night use?

Acoustic measurement places S&P PCD110XP at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories