The S&P PCD110XP (PCD) moves 140 CFM at 0.1 in. w.g. (146.6 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 11.5 CFM/W efficacy, sizing bathrooms up to 146 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCD110XP Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 140 / 146.6 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 11.5 CFM/W (#106/1,145)
- Static Retention
- 104.7% @ 0.25"
- Motor Draw
- 12.2 W (4.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does S&P PCD110XP vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P PCD110XP (EPA filing PD #2397153) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 146.6 CFM out of 140 CFM (104.7% retention, 17.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: S&P registers 29 certified models, with SKU PCD110XP (series: PCD) (PD #2397153) certified since 2022-05-20. Lighting kit: No. At 11.5 CFM/W (#106 of 1,145, top 10.0% of 1,145 rated models, more efficient than 90.0% of rated models, 6.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and ACIQ AEPD140-3 (140.0 CFM).
How does duct geometry alter S&P PCD110XP static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to S&P PCD110XP?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for S&P PCD110XP alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PCD110XP / PCD | PD ID 2397153 (Qualified 2022-05-20) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (146.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can S&P PCD110XP ventilate safely?
Sizing outputs below convert S&P PCD110XP tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 146 sq ft | 1 CFM/sq ft @ 146.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 130 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 96 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.9 kWh/yr (~$17.10/yr) | 12.2 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match S&P PCD110XP closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| ACIQ AEPD140-3 | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| CFM TF140-EC | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| Haier QVE110DTWW | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| Ortech ODD-110-18PB | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
Will S&P PCD110XP clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether S&P PCD110XP satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does S&P PCD110XP fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering S&P PCD110XP.
Limitations & Who Should Skip
- Steam or walk-in tub room > 96 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 146 sq ft with 8-ft ceilings (130 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern S&P PCD110XP?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting S&P PCD110XP.
Does running S&P PCD110XP continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of S&P PCD110XP draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can S&P PCD110XP pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCD110XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P PCD110XP?
S&P PCD110XP features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P PCD110XP's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCD110XP's safe coverage footprint from 50 sq ft to 44 sq ft.
Is S&P PCD110XP code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), S&P PCD110XP clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than S&P PCD110XP?
Do not force S&P PCD110XP into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does S&P PCD110XP retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, S&P PCD110XP produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Will S&P PCD110XP disturb adjacent bedrooms during night use?
Acoustic measurement places S&P PCD110XP at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)