Skip to main content
Grant Estimator

GE JVX5305DJBB Exhaust Fan Specifications

ENERGY STAR PD #2399335 · Range Hood · Qualified 2022-07-29
Verified Specification Summary

The GE JVX5305DJBB (JVX5305DJBB) moves 139 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 3.4 CFM/W efficacy, sizing bathrooms up to 139 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside GE JVX5305DJBB Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
139 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.4 CFM/W (#1,060/1,145)
Static Retention
0.1" test only
Motor Draw
40.9 W (14.9 kWh/yr)
Duct & Tier
3.25 x 10 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does GE JVX5305DJBB vs. 1,145-Model ENERGY STAR Benchmarks show?

GE JVX5305DJBB (EPA filing PD #2399335) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 139 CFM (#227 of 1,145 certified models) via a 3.25 x 10 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 10 in. rectangular housing before entering attic bays.

Certification audit confirms GE JVX5305DJBB (series: JVX5305DJBB) under PD #2399335 (1 model registered, 2022-07-29). Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 40.9 watts, about 14.9 kWh/yr (~$2.38/yr at $0.16/kWh) for 1 hr/day shower timers or 358.3 kWh/yr (~$57.33/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).

How does duct geometry alter GE JVX5305DJBB static pressure?

Smooth 3.25 x 10 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to GE JVX5305DJBB?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for GE JVX5305DJBB alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share GE (1 model) ENERGY STAR Certified Partner
Model Number & Series JVX5305DJBB / JVX5305DJBB PD ID 2399335 (Qualified 2022-07-29)
Duct Connection 3.25 x 10 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (139 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can GE JVX5305DJBB ventilate safely?

Sizing outputs below convert GE JVX5305DJBB tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for GE JVX5305DJBB
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 139 sq ft1 CFM/sq ft @ 139 CFM
Tall Bath (9-ft Ceiling)Up to 123 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 89 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)14.9 kWh/yr (~$2.38/yr)40.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2358.3 kWh/yr (~$57.33/yr)40.9 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match GE JVX5305DJBB closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter

Will GE JVX5305DJBB clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether GE JVX5305DJBB satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Who should not install GE JVX5305DJBB in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting GE JVX5305DJBB for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 89 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 139 sq ft with 8-ft ceilings (123 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 3.25 x 10 in. rectangular

What key rules and numbers govern GE JVX5305DJBB?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting GE JVX5305DJBB.

How does GE JVX5305DJBB sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, GE JVX5305DJBB produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define GE JVX5305DJBB?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can GE JVX5305DJBB pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from GE JVX5305DJBB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing GE JVX5305DJBB?

GE JVX5305DJBB features a 3.25 x 10 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change GE JVX5305DJBB's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing GE JVX5305DJBB's safe coverage footprint from 50 sq ft to 44 sq ft.

Does GE JVX5305DJBB satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), GE JVX5305DJBB clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is GE JVX5305DJBB undersized or poorly matched for a bath renovation?

Skip GE JVX5305DJBB if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check GE JVX5305DJBB CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, GE JVX5305DJBB registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3.25 x 10 in. rectangular duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories