Tested under HVI protocols, the Field Controls FAPV-L exhaust unit achieves 138.1 CFM at 0.1 in. w.g. (106 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 5.0 CFM/W efficacy, covering standard baths up to 106 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Field Controls FAPV-L Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 138.1 / 106 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.0 CFM/W (#514/1,145)
- Static Retention
- 76.8% @ 0.25"
- Motor Draw
- 27.6 W (10.1 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Field Controls FAPV-L vs. 1,145-Model ENERGY STAR Benchmarks show?
Field Controls FAPV-L (EPA filing PD #3892682) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Expect noticeable duct drag: airflow moves from 138.1 CFM open-air to 106 CFM at 0.25 in. w.g. (76.8% retention, 10.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Field Controls maintains 1 active ENERGY STAR blower; FAPV-L (series: FAPV-L) (PD #3892682) gained qualification on 2025-01-09. Lighting kit: No. At 5.0 CFM/W (#514 of 1,145, top 45.2% of 1,145 rated models, more efficient than 54.8% of rated models, 0.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 27.6 watts, about 10.1 kWh/yr (~$1.62/yr at $0.16/kWh) for 1 hr/day shower timers or 241.8 kWh/yr (~$38.69/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).
What attic duct routing preserves Field Controls FAPV-L CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Field Controls FAPV-L, preventing premature peeling paint and mold growth.
How does Field Controls FAPV-L measure up on airflow and noise ratings?
Each row below breaks down Field Controls FAPV-L certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Field Controls (1 model) | ENERGY STAR Certified Partner |
| Model Number & Series | FAPV-L / FAPV-L | PD ID 3892682 (Qualified 2025-01-09) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (106 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Field Controls FAPV-L CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.1 kWh/yr (~$1.62/yr) | 27.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 241.8 kWh/yr (~$38.69/yr) | 27.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Field Controls FAPV-L?
Compare Field Controls FAPV-L side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
Can you size Field Controls FAPV-L for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Field Controls FAPV-L verified capacity.
Which bath layouts should avoid specifying Field Controls FAPV-L?
Match Field Controls FAPV-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 106 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around ENERGY STAR sones up to 106 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Field Controls FAPV-L?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Field Controls FAPV-L.
What bathroom square footage can Field Controls FAPV-L ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Field Controls FAPV-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Field Controls FAPV-L run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Field Controls FAPV-L.
What happens to Field Controls FAPV-L CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Field Controls FAPV-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Field Controls FAPV-L sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Field Controls FAPV-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Field Controls FAPV-L cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Field Controls FAPV-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Field Controls FAPV-L pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Field Controls FAPV-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Field Controls FAPV-L?
Field Controls FAPV-L features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Field Controls FAPV-L's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Field Controls FAPV-L's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)