Field Controls FAPV-L Exhaust Fan Specifications

ENERGY STAR PD #3892682 · In-line (single-port) · Qualified 2025-01-09
Verified Specification Summary

Tested under HVI protocols, the Field Controls FAPV-L exhaust unit achieves 138.1 CFM at 0.1 in. w.g. (106 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 5.0 CFM/W efficacy, covering standard baths up to 106 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Field Controls FAPV-L Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
138.1 / 106 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.0 CFM/W (#514/1,145)
Static Retention
76.8% @ 0.25"
Motor Draw
27.6 W (10.1 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Field Controls FAPV-L vs. 1,145-Model ENERGY STAR Benchmarks show?

Field Controls FAPV-L (EPA filing PD #3892682) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Expect noticeable duct drag: airflow moves from 138.1 CFM open-air to 106 CFM at 0.25 in. w.g. (76.8% retention, 10.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Field Controls maintains 1 active ENERGY STAR blower; FAPV-L (series: FAPV-L) (PD #3892682) gained qualification on 2025-01-09. Lighting kit: No. At 5.0 CFM/W (#514 of 1,145, top 45.2% of 1,145 rated models, more efficient than 54.8% of rated models, 0.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 27.6 watts, about 10.1 kWh/yr (~$1.62/yr at $0.16/kWh) for 1 hr/day shower timers or 241.8 kWh/yr (~$38.69/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

What attic duct routing preserves Field Controls FAPV-L CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Field Controls FAPV-L, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Field Controls FAPV-L measure up on airflow and noise ratings?

Each row below breaks down Field Controls FAPV-L certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Field Controls (1 model) ENERGY STAR Certified Partner
Model Number & Series FAPV-L / FAPV-L PD ID 3892682 (Qualified 2025-01-09)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (106 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Field Controls FAPV-L CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Field Controls FAPV-L
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 106 sq ft1 CFM/sq ft @ 106 CFM
Tall Bath (9-ft Ceiling)Up to 94 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 56 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.1 kWh/yr (~$1.62/yr)27.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2241.8 kWh/yr (~$38.69/yr)27.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Field Controls FAPV-L?

Compare Field Controls FAPV-L side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter

Can you size Field Controls FAPV-L for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Field Controls FAPV-L verified capacity.

Which bath layouts should avoid specifying Field Controls FAPV-L?

Match Field Controls FAPV-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 106 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 106 sq ft
  • Optimal use: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Field Controls FAPV-L?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Field Controls FAPV-L.

What bathroom square footage can Field Controls FAPV-L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Field Controls FAPV-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Field Controls FAPV-L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Field Controls FAPV-L.

What happens to Field Controls FAPV-L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Field Controls FAPV-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does Field Controls FAPV-L sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Field Controls FAPV-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Field Controls FAPV-L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Field Controls FAPV-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Field Controls FAPV-L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Field Controls FAPV-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Field Controls FAPV-L?

Field Controls FAPV-L features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Field Controls FAPV-L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Field Controls FAPV-L's safe coverage footprint from 50 sq ft to 44 sq ft.