Air King F130D Exhaust Fan Specifications

ENERGY STAR PD #2347885 · In-line (single-port) · Qualified 2019-10-04
Verified Specification Summary

In EPA dataset 8dv7-nngq, Air King F130D tests at 130 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 5.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 130 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King F130D Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.4 CFM/W (#491/1,145)
Static Retention
0.1" test only
Motor Draw
24.1 W (8.8 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King F130D vs. 1,145-Model ENERGY STAR Benchmarks show?

Air King F130D (EPA filing PD #2347885) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Air King's 62-unit lineup, F130D (series: Air King) carries PD #2347885 dating to 2019-10-04. Lighting kit: No. At 5.4 CFM/W (#491 of 1,145, top 43.1% of 1,145 rated models, more efficient than 56.9% of rated models, 0.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 24.1 watts, about 8.8 kWh/yr (~$1.41/yr at $0.16/kWh) for 1 hr/day shower timers or 211.1 kWh/yr (~$33.78/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

Why avoid unvented attic termination with Air King F130D?

Under ASHRAE 62.2 best practice, Air King F130D needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Air King F130D?

Before cutting ceiling drywall or sizing attic transitions for Air King F130D, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series F130D / Air King PD ID 2347885 (Qualified 2019-10-04)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (130 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Air King F130D?

Bathroom ventilation sizing below maps Air King F130D motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Air King F130D
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 130 sq ft1 CFM/sq ft @ 130 CFM
Tall Bath (9-ft Ceiling)Up to 115 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 80 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.8 kWh/yr (~$1.41/yr)24.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2211.1 kWh/yr (~$33.78/yr)24.1 W x 8,760 hrs / 1,000

What peer models sit nearest Air King F130D in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King F130D.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Greenheck SP-B110ES 118 / 100 CFM 1.5 sones 4.0 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular

What percentage of room demand does Air King F130D cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King F130D tested delivery.

Where should contractors skip Air King F130D on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Air King F130D carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 130 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around ENERGY STAR sones up to 130 sq ft
  • Works well for: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Air King F130D?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King F130D.

How loud is Air King F130D compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Air King F130D produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Air King F130D consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Air King F130D draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Air King F130D pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King F130D's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King F130D?

Air King F130D features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King F130D's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King F130D's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Air King F130D score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Air King F130D delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Air King F130D?

Rule out Air King F130D when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Air King F130D capacity?

Because static drag at 0.25 in. w.g. lowers Air King F130D from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)