Skip to main content
Grant Estimator

AERO PURE ABF110DHL5W Exhaust Fan Specifications

ENERGY STAR PD #2338638 · Bathroom/Utility Room · Qualified 2019-05-17
Verified Specification Summary

In EPA dataset 8dv7-nngq, AERO PURE ABF110DHL5W tests at 110 CFM free discharge (93.9 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 7.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 93 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF110DHL5W Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 93.9 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.4 CFM/W (#392/1,145)
Static Retention
85.4% @ 0.25"
Motor Draw
14.9 W (5.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AERO PURE ABF110DHL5W vs. 1,145-Model ENERGY STAR Benchmarks show?

AERO PURE ABF110DHL5W (EPA filing PD #2338638) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 93.9 CFM out of 110 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

AERO PURE maintains 14 active ENERGY STAR blowers; ABF110DHL5W (series: ABF) (PD #2338638) gained qualification on 2019-05-17. Lighting kit: Yes. At 7.4 CFM/W (#392 of 1,145, top 34.8% of 1,145 rated models, more efficient than 65.2% of rated models, 2.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.9 watts, about 5.4 kWh/yr (~$0.86/yr at $0.16/kWh) for 1 hr/day shower timers or 130.5 kWh/yr (~$20.88/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Delta 100LED (100.0 CFM).

Why avoid unvented attic termination with AERO PURE ABF110DHL5W?

Under ASHRAE 62.2 best practice, AERO PURE ABF110DHL5W needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern AERO PURE ABF110DHL5W?

Before cutting ceiling drywall or sizing attic transitions for AERO PURE ABF110DHL5W, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AERO PURE (14 models) ENERGY STAR Certified Partner
Model Number & Series ABF110DHL5W / ABF PD ID 2338638 (Qualified 2019-05-17)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (93.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit AERO PURE ABF110DHL5W?

Bathroom ventilation sizing below maps AERO PURE ABF110DHL5W motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for AERO PURE ABF110DHL5W
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 93 sq ft1 CFM/sq ft @ 93.9 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 43 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.4 kWh/yr (~$0.86/yr)14.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2130.5 kWh/yr (~$20.88/yr)14.9 W x 8,760 hrs / 1,000

What peer models sit nearest AERO PURE ABF110DHL5W in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AERO PURE ABF110DHL5W.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Delta 100LED 100 / 75 CFM 1.5 sones 7.4 CFM/W 4 in. diameter
Delta GBR100LED 100 / 75 CFM 1.5 sones 7.4 CFM/W 4 in. diameter
Delta ITG100 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter
Utilitech 7131-04 100 / 88 CFM 1.5 sones 7.6 CFM/W 4 in. diameter

What percentage of room demand does AERO PURE ABF110DHL5W cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AERO PURE ABF110DHL5W tested delivery.

Which bath layouts should avoid specifying AERO PURE ABF110DHL5W?

Match AERO PURE ABF110DHL5W directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 93.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 93 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for AERO PURE ABF110DHL5W?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AERO PURE ABF110DHL5W.

Where does AERO PURE ABF110DHL5W run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with AERO PURE ABF110DHL5W.

What happens to AERO PURE ABF110DHL5W CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, AERO PURE ABF110DHL5W moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does AERO PURE ABF110DHL5W sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, AERO PURE ABF110DHL5W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does AERO PURE ABF110DHL5W cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running AERO PURE ABF110DHL5W 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can AERO PURE ABF110DHL5W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF110DHL5W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AERO PURE ABF110DHL5W?

AERO PURE ABF110DHL5W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AERO PURE ABF110DHL5W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF110DHL5W's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can AERO PURE ABF110DHL5W ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), AERO PURE ABF110DHL5W covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories