The Greenheck CSP-A125 (CSP) moves 113 CFM at 0.1 in. w.g. (103 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 5.2 CFM/W efficacy, sizing bathrooms up to 103 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck CSP-A125 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 113 / 103 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.2 CFM/W (#499/1,145)
- Static Retention
- 91.2% @ 0.25"
- Motor Draw
- 21.7 W (7.9 kWh/yr)
- Duct & Tier
- 6 x 8 in. rectangular · Standard

What does Greenheck CSP-A125 vs. 1,145-Model ENERGY STAR Benchmarks show?
Greenheck CSP-A125 (EPA filing PD #2364774) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 103 CFM out of 113 CFM (91.2% retention, 3.5 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.
Inside Greenheck's 31-unit lineup, CSP-A125 (series: CSP) carries PD #2364774 dating to 2020-08-10. Lighting kit: No. At 5.2 CFM/W (#499 of 1,145, top 44.2% of 1,145 rated models, more efficient than 55.8% of rated models, 0.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 21.7 watts, about 7.9 kWh/yr (~$1.26/yr at $0.16/kWh) for 1 hr/day shower timers or 190.1 kWh/yr (~$30.42/yr) continuously. Closest competing matches include Tech Drive TD-BF-10 (110.0 CFM) and Tech Drive TD-BF-10-H (110.0 CFM).
How does duct geometry alter Greenheck CSP-A125 static pressure?
Smooth 6 x 8 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Greenheck CSP-A125?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Greenheck CSP-A125 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenheck (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | CSP-A125 / CSP | PD ID 2364774 (Qualified 2020-08-10) |
| Duct Connection | 6 x 8 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (103 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Greenheck CSP-A125 ventilate safely?
Sizing outputs below convert Greenheck CSP-A125 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103 CFM |
| Tall Bath (9-ft Ceiling) | Up to 91 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.9 kWh/yr (~$1.26/yr) | 21.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 190.1 kWh/yr (~$30.42/yr) | 21.7 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Greenheck CSP-A125 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-10 | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TG-H | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TGHS | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-04-L(BL) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |
Will Greenheck CSP-A125 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Greenheck CSP-A125 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
What plumbing or duct constraints rule out Greenheck CSP-A125?
Compare where Greenheck CSP-A125 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 53 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 103 sq ft with 8-ft ceilings (91 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 6 x 8 in. rectangular
What key rules and numbers govern Greenheck CSP-A125?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Greenheck CSP-A125.
Is Greenheck CSP-A125 quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Greenheck CSP-A125 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Greenheck CSP-A125 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Greenheck CSP-A125 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck CSP-A125's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenheck CSP-A125?
Greenheck CSP-A125 features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenheck CSP-A125's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck CSP-A125's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Greenheck CSP-A125 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Greenheck CSP-A125 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Greenheck CSP-A125 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Greenheck CSP-A125 lacks adequate reserve.
How does Greenheck CSP-A125 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Greenheck CSP-A125 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 x 8 in. rectangular rigid metal ducting protects real exhaust.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)